More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps while retaining particulates at a fine, gravimetric-grade cutoff and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Basis weight between 75 and 96 grams per square meter
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Compatible with hot filtration in gravimetric workflows
- Rated ash content of 0.01 percent or below
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Request a quality certificate or lot documentation on your order from our support team, any time.
- Diameter
- 150mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 589/3
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.01%
- Nominal Basis Weight (g/ m²)
- 84g/m²
- Pack Count
- 100
- Particle Retention
- <2um
- Pore Size (µm)
- 2
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.