    PTFE Capsule Filters - 2602S

    PTFE capsule filters bring the chemical inertness required for solvent processing and gas filtration into a disposable, integrity-testable format suited to regulated environments. Underpinning this performance, the chemically inert PTFE membrane within the capsule housing resists degradation by virtually all organic solvents, strong acids, and alkaline solutions, enabling filtration of the most aggressive process fluids. In turn, the result is a filtration process that eliminates cleaning validation, reduces changeover time, and provides batch-to-batch consistency through factory-tested, integrity-verified devices.

    Key PTFE Membrane Characteristics

    • PTFE membrane chemistry withstands autoclave temperatures, supporting sterilization protocols where both the membrane and housing construction are rated for steam exposure.
    • Chemical inertness of the PTFE membrane ensures that filtered solvents and gases pass through without extractable contamination, meeting the purity requirements of HPLC mobile phase preparation and analytical applications.
    • The pleated PTFE membrane configuration within the capsule housing provides sufficient surface area for production-scale solvent filtration without the pressure drops associated with flat disc PTFE devices.
    • PTFE membrane capsules resist degradation by virtually all organic solvents, strong acids, bases, and oxidizing agents, providing universal chemical compatibility for aggressive filtration applications.
    • Non-sterile configuration accommodates laboratory and industrial applications where the capsule filter serves a clarification or protection function rather than a sterilizing-grade barrier role.

    Key Capsule Construction Features

    • Sanitary flange connections provide the tri-clamp compatible interface required for integration into pharmaceutical and biopharmaceutical process piping systems.
    • Polypropylene capsule housing supports autoclave sterilization at 121 degrees Celsius and withstands gamma irradiation exposure, accommodating both user-sterilized and factory-sterilized device configurations.
    • Polypropylene capsule housing provides broad chemical compatibility from pH 1 to 14, resisting the acids, bases, and process chemicals that degrade alternative housing materials.
    • Thermally fused polypropylene construction eliminates adhesives, binders, and O-rings from the fluid path, reducing extractable contamination and simplifying material qualification.

    When your filtration protocol calls for a validated, integrity-testable barrier that arrives ready to connect and begins filtering immediately, the capsule format delivers that capability without the overhead of traditional filter assemblies. Here, if your workflow involves organic solvents, aggressive reagents, or process gas streams, the universal chemical resistance of PTFE membrane construction handles the harshest conditions your application presents. Make the decision for consistency and reliability, ensuring that your laboratory maintains its reputation for high-quality, error-free output.

    Sterilization Guidance

    Standard autoclave cycles at 121 degrees Celsius are compatible with the polypropylene housing and membrane assembly, allowing preparation for sterile applications at the point of use.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7 psi
    Burst Pressure (psi)
    60 psi
    Capsule Format
    Polycap TF 36
    Compliance Standards
    ISO 9001
    Construction
    Polypropylene
    Diameter
    3.6 cm
    Filling Bell (Yes/ No)
    No
    Filtration Area
    430 cm²
    Holdup Volume
    10 mL
    Inlet Connection
    1-1/2 in. sanitary flange
    Length
    10.4 cm
    Material
    PTFE
    Max Batch Volume
    Medium-volume batch processing
    Maximum Operating Pressure
    60 psi
    Maximum Operating Temperature (°C)
    121 °C
    Outlet Connection
    1-1/2 in. sanitary flange
    Pack Count
    5
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclave
    Vent (Yes/ No)
    No
    Wettability
    Hydrophobic
    • Chemical Processing - Filtration of strong acids, bases, and aggressive organic chemicals that degrade PES, PVDF, and nylon membranes.
    • Solvent Filtration - Chemical-resistant filtration of HPLC mobile phases, aggressive organic solvents, and corrosive reagent solutions.
    • Solvent Recovery - Clarification of recycled organic solvents to remove particulates accumulated during previous processing operations.
    • Tank Venting - Hydrophobic membrane barrier prevents microbial ingress while allowing pressure equalization in process tank headspaces.
    • Vent Protection - Membrane barrier filtration for fermentation vessel exhaust and bioreactor off-gas systems in bioprocessing facilities.