Chat with us, powered by LiveChat

Secure Checkout
PolyCap TC 75 PES Capsule Filter

Thumbnail Filmstrip of PolyCap TC 75 PES Capsule Filter Images

    Purchase PolyCap TC 75 PES Capsule Filter

    PolyCap TC 75 PES Capsule Filter SKU: 6715-7582

    $152.95
    Ships in 4 business days
     

    Polyethersulfone (PES) Capsule Filters - 6715-7582

    Ultra-low protein binding and broad pH compatibility from 1 to 14 make PES capsule filters the preferred membrane choice for processing biological solutions at production scale. Designed for laboratory performance, asymmetric PES membrane construction captures contaminants at the upstream surface while maintaining open pore channels beneath, extending capsule service life and reducing the frequency of mid-batch device changes. Consequently, the outcome is a validated filtration barrier that arrives ready for process integration, supporting the single-use manufacturing strategies adopted by modern pharmaceutical and biotechnology facilities.

    Key Polyethersulfone (PES) Membrane Characteristics

    • PES membrane capsules deliver broad pH compatibility from 1 to 14, accommodating the full range of buffers, media, and cleaning solutions encountered in biopharmaceutical processing.
    • PES capsule filters achieve flow rates that support large-batch processing without the mid-run device changes that disrupt sterile workflows and introduce contamination risk.
    • Ultra-low protein binding characteristics of the PES membrane minimize adsorptive losses, preserving the concentration and biological activity of filtered proteins, antibodies, and growth factors.
    • Pre-sterilized capsule packaging maintains sterility through storage, transport, and connection, providing a validated sterile barrier at the point of use.
    • The asymmetric pore structure of PES membranes captures contaminants at the upstream surface while maintaining open downstream channels, extending capsule throughput before reaching differential pressure limits.

    Key Capsule Construction Features

    • Stepped hose barb connections accommodate tubing with inner diameters from 1/4 to 1/2 inch, providing secure push-fit attachment without requiring clamps or specialized fittings.
    • Single-use polypropylene capsule construction eliminates cleaning validation requirements, reducing the regulatory burden and turnaround time associated with reusable stainless steel filter housings.
    • Polypropylene housing materials provide documented biocompatibility and low extractable profiles, supporting integration into pharmaceutical and food-processing filtration applications.
    • The sealed polypropylene housing is individually integrity-tested during manufacturing, verifying membrane installation and housing seal quality before the device leaves the production facility.

    From method development through scale-up to production, your capsule filter choice defines the balance between membrane performance, process integration, and the regulatory documentation trail that supports each filtration event. In these cases, if your process involves aqueous biologicals, the ultra-low protein binding and broad pH compatibility of PES membrane construction protect your product while sustaining the flow rates your batch schedule requires. Elevate the quality of your analytical data today by standardizing on a filtration product built to meet the exact specifications of your applications.

    Sterilization Guidance

    Sealed sterile packaging preserves validated sterility throughout storage and transport, providing a documented sterile barrier that is ready for use at the point of need.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    40 psi
    Burst Pressure (psi)
    60 psi
    Capsule Format
    Polycap TC 75
    Compliance Standards
    ISO 9001; HIMA Challenge Test
    Construction
    Polypropylene
    Diameter
    7.5 cm
    Filling Bell (Yes/ No)
    Yes
    Filtration Area
    1100 cm²
    Holdup Volume
    125 mL
    Inlet Connection
    1/4 to 3/8 in. stepped barb
    Material
    PES
    Max Batch Volume
    Large-volume batch processing
    Maximum Operating Pressure
    60 psi
    Maximum Operating Temperature (°C)
    121 °C
    Outlet Connection
    1/4 to 3/8 in. stepped barb
    Pack Count
    1
    Pore Size (µm)
    0.2
    Pre-filter Pore Size
    0.8
    Prefilter (Yes/No)
    Yes
    Sterility
    Sterile
    Sterilization
    Do not re-sterilize (autoclavable if sterility expires)
    Vent (Yes/ No)
    No
    Wettability
    Hydrophilic
    • Reagent Filtration - Removal of particulates and contaminants from laboratory reagents and process solutions before downstream use.
    • Serum Processing - Capsule filtration of animal sera and biological supplements for cell culture and diagnostic reagent applications.
    • Buffer Processing - Large-volume filtration of pharmaceutical buffers and process solutions with broad pH compatibility across pH 1-14.
    • Biologics Protection - Ultra-low protein binding preserves antibody and growth factor concentrations through the membrane retention step.
    • Process Intermediates - In-line capsule filtration of pharmaceutical intermediates with validated retention and low adsorptive losses.
    • Water Purification - Membrane-grade filtration of purified water and water-for-injection systems in pharmaceutical manufacturing facilities.