Whatman Anotop Aluminum Oxide Syringe Filters, 0.02 µm, 10 mm, 50/Pk - 6809-1102
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. Many syringe filters ship with lot-specific quality documentation, giving analysts documented traceability beyond what an ad hoc bulk filtration setup typically provides. Anotop's ceramic membrane becomes visibly clear the moment it is wetted while slowing early bacterial colonization compared to a smooth surface and holds a nondeformable, straight pore geometry. The polypropylene housing preserves sample chemistry across the flow path while sustaining efficient flow on viscous samples and stays inert across common laboratory solvents. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.
Membrane Characteristics
- Extractable content stays minimal without interfering with downstream detection
- Uniform capillary pore array gives high pore density without lateral crossover
- Absolute pore-size rating holds consistent across every protocol
- Low intrinsic autofluorescence limits background signal in fluorescence work
- Membrane surface turns optically transparent once wetted with liquid
Housing Characteristics
- Polypropylene housing retains its chemical integrity under vaporized hydrogen peroxide decontamination cycles used in aseptic processing isolators
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Each housing is factory-sterilized and sealed individually to maintain sterility through the supply chain
- The seal formed against the membrane blocks bypass at rated operating pressure
A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Upstream sample clarification keeps your separations clean and reproducible so your filtrate reaches the column clean. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.
Sterilization Guidance
The device arrives factory sterile and is intended for single-use sample preparation.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.9 bar (100 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 10mm
- Filtration Area
- 0.78cm²
- Holdup Volume
- <20µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.02
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophilic
- Liposome Extrusion - Size liposomes into uniform vesicles precisely, enabling consistent drug delivery research with defined pore structures.
- Single-Particle Analysis - Concentrates nanoparticles from dilute suspensions for tunable resistive pulse sensing and nanoparticle tracking.
- Flow Cytometry Prep - Removes residual debris and aggregates from cell suspension buffers before immunophenotyping and bead-based multiplex assays.
- Electron Microscopy Prep - Image retained particulates directly, using the electron-beam-stable ceramic surface for SEM and TEM sample preparation.
- Protein Aggregate Removal - Strips antibody and biologic formulations of aggregate species before SEC-MALS and DLS molecular weight characterization.
- Virus Filtration - Separate viruses and bacteriophages effectively, utilizing precise pore size exclusion for accurate biological separations.