Whatman Anotop Aluminum Oxide Syringe Filters, 0.1 µm, 10 mm, 50/Pk - 6809-1112
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Aluminum oxide's straight channels pull samples by capillary action while delivering sterile-grade retention at sub-micron pore sizes and handles aqueous and solvent samples cleanly. The polypropylene housing presses snugly against the membrane during the pass and is supplied pre-sterilized in individual packaging for sterile sample preparation. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Uniform capillary pore array gives high pore density without lateral crossover
- Anodized alumina matrix contains no monomers, plasticizers, adhesives, or wetting agents
- Extractable content stays minimal without interfering with downstream detection
- Chemical stability in aqueous solutions spans a pH 3 to 9 range
- Inorganic ceramic structure resists solvent swelling common to polymer membrane materials
Housing Characteristics
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure.
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream.
- Resists stress cracking from aqueous salt and buffer solutions
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening.
Reproducible separations start with samples that reach the column free of particulates. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Ask about Whatman's quality documentation to confirm your filtration step meets a recognized laboratory-science standard.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.2 bar (90 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 10mm
- Filtration Area
- 0.78cm²
- Holdup Volume
- <20µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophilic
- Protein Aggregate Removal - Strips antibody and biologic formulations of aggregate species before SEC-MALS and DLS molecular weight characterization.
- Vaccine Particle QC - Filters virus-like particle and VLP formulations to remove aggregates before particle size distribution and potency analysis.
- Small Volume CE - Filter tiny sample volumes for capillary electrophoresis, minimizing hold-up volume to conserve valuable sample material.
- HPLC Solvent Filtration - Filter chromatography mobile phases and solvents reliably, resisting degradation from aggressive organic reagents.
- NMR Sample Filtration - Delivers aggregate-free aqueous filtrates with no organic extractables interfering with proton or carbon NMR spectra.
- Flow Cytometry Prep - Removes residual debris and aggregates from cell suspension buffers before immunophenotyping and bead-based multiplex assays.