Whatman Anotop Aluminum Oxide Syringe Filters, 0.1 µm, 10 mm, 50/Pk - 6809-1112
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. The Anotop membrane turns optically clear once wetted with liquid and presents a high-density honeycomb pore structure. Pre-sterilized polypropylene construction is individually wrapped for direct use in sterile workflows while shedding virtually no extractable material into the sample and stands firm against aqueous acids, bases, and alcohols during regular handling. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Absolute pore-size rating holds consistent across every protocol
- Mineral oxide chemistry gives proteins little to adsorb onto
- Rigid inorganic structure withstands high temperatures with minimal extractables
- Low intrinsic autofluorescence limits background signal in fluorescence work
- Naturally hydrophilic ceramic surface wets without pre-wetting in aqueous samples
Housing Characteristics
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Standardized luer connection geometry provides secure engagement with standard syringe tips
Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request a quote on Whatman filtration products from the Tisch Scientific team.
Sterilization Guidance
Sterile single-use packaging removes any in-lab sterilization preparation step.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.2 bar (90 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 10mm
- Filtration Area
- 0.78cm²
- Holdup Volume
- <20µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophilic
- Fluorescence Spectroscopy Prep - Removes scattering particles from chromophore solutions for clean emission spectra in cuvette measurements.
- AFM Sample Deposition - Removes large aggregates from colloidal suspensions before deposition on mica for atomic force microscopy surface imaging.
- Protein Aggregate Removal - Strips antibody and biologic formulations of aggregate species before SEC-MALS and DLS molecular weight characterization.
- Clinical Biomarker Prep - Removes debris from plasma and serum aliquots for protein and small-molecule biomarker profiling by mass spectrometry.
- Gravimetric Solids Testing - Determine particulate mass accurately, using a non-hygroscopic ceramic that resists moisture-driven drift.
- Single-Particle Analysis - Concentrates nanoparticles from dilute suspensions for tunable resistive pulse sensing and nanoparticle tracking.