Anotop 25mm Syringe Filter, 0.02 um, 50 Pk

Thumbnail Filmstrip of Anotop 25mm Syringe Filter, 0.02 um, 50 Pk Images

    Purchase Anotop 25mm Syringe Filter, 0.02 um, 50 Pk

    Anotop 25mm Syringe Filter, 0.02 um, 50 Pk
    Whatman SKU: 6809-2002

    $748.95
    Ships in 4 business days
     

    Whatman Anotop Aluminum Oxide Syringe Filters, 0.02 µm, 25 mm, 50/Pk - 6809-2002

    Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. The thin ceramic membrane holds a nondeformable, straight pore geometry while limiting bacterial attachment through enhanced electrostatic repulsion at the nanoscale and keep each molecule's channel-wall contact brief. The PP housing sustains efficient flow on viscous samples while shedding virtually no extractable material into the sample and leaves no seam for sample to bypass the membrane. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Membrane Characteristics

    • Anodized alumina matrix contains no monomers, plasticizers, adhesives, or wetting agents
    • Low intrinsic autofluorescence limits background signal in fluorescence work
    • Uniform capillary pore array gives high pore density without lateral crossover
    • Mineral oxide chemistry gives proteins little to adsorb onto
    • Membrane surface turns optically transparent once wetted with liquid

    Housing Characteristics

    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping

    Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Upstream buffer clarification keeps your run from stalling on particulates that slipped through while keeping the filtrate analytically clean. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    6.9 bar (100 psi)
    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Anopore (Aluminum Oxide)
    Diameter
    25mm
    Filtration Area
    4.15cm²
    Holdup Volume
    <150µl
    Material
    Anopore
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    40°C
    Pack Count
    50
    Pore Size (µm)
    0.02
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Protein Aggregate Removal - Strips antibody and biologic formulations of aggregate species before SEC-MALS and DLS molecular weight characterization.
    • Nucleic Acid Clarification - Removes particulates from plasmid and oligonucleotide preparations ahead of gel electrophoresis and UV quantitation.
    • Environmental DNA Sampling - Concentrates aquatic environmental DNA from water samples for downstream eDNA metabarcoding and biodiversity monitoring.
    • Carbohydrate Prep - Prepare saccharide samples for analysis, ensuring no organic extractables interfere with sensitive carbohydrate detection.
    • Vaccine Particle QC - Filters virus-like particle and VLP formulations to remove aggregates before particle size distribution and potency analysis.
    • Biopharmaceutical Clarification - Filters bioprocess buffers and excipient solutions to meet the lowest achievable particulate specifications.