Whatman Anotop Aluminum Oxide Syringe Filters, 0.1 µm, 25 mm, 50/Pk - 6809-2112
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. Anodized alumina carries native hydrophilic chemistry built into the oxide itself while tolerating high temperatures and broad solvent ranges and confines bacteria within its rated ceramic pore diameter. Polypropylene housing is factory-sterilized and packaged to preserve that state until use and presses snugly against the membrane during the pass. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Membrane Characteristics
- Inorganic ceramic structure resists solvent swelling common to polymer membrane materials
- Absolute pore-size rating holds consistent across every protocol
- Rigid inorganic structure withstands high temperatures with minimal extractables
- Membrane surface turns optically transparent once wetted with liquid
- Anodized alumina matrix contains no monomers, plasticizers, adhesives, or wetting agents
Housing Characteristics
- Withstands ethylene oxide gas sterilization without embrittlement or structural damage
- Resists stress cracking from aqueous salt and buffer solutions
- Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
- Translucent housing wall allows visual confirmation of sample flow during filtration
An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Upstream buffer clarification keeps your run from stalling on particulates that slipped through across routine and validated analytical methods. Request volume pricing and stock availability on your filtration product selection from the Tisch Scientific team.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.2 bar (90 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 25mm
- Filtration Area
- 4.15cm²
- Holdup Volume
- <150µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Polymer Removal - Remove high molecular weight polymers efficiently, utilizing the unique inorganic membrane structure for difficult separations.
- Drug Nanoparticle QC - Removes oversized aggregates from nanoparticle drug carriers before size and zeta potential analysis for formulation release.
- Low-Bleed IC Sampling - Filter samples for ion chromatography confidently, as the alumina membrane leaches minimal anions into the analyte stream.
- Protein Aggregate Removal - Strips antibody and biologic formulations of aggregate species before SEC-MALS and DLS molecular weight characterization.
- Wastewater Solids Monitoring - Retains and recovers suspended solids and microbial contaminants from effluent samples for permit limit verification.
- Geochemical Water Analysis - Filters water and soil leachates to resolve the dissolved fraction for ICP-MS and atomic spectroscopy quantitation.