Chat with us, powered by LiveChat

Secure Checkout
Anotop Plus 10mm Syringe Filter w/GMF PreFilter, 0.1um, 50 Pk

Thumbnail Filmstrip of Anotop Plus 10mm Syringe Filter w/GMF PreFilter, 0.1um, 50 Pk Images

    Purchase Anotop Plus 10mm Syringe Filter w/GMF PreFilter, 0.1um, 50 Pk

    Anotop Plus 10mm Syringe Filter w/GMF PreFilter, 0.1um, 50 Pk
    Whatman SKU: 6809-3012

    $603.99
    Ships in 4 business days
     

    Whatman Anotop Aluminum Oxide Syringe Filters, 0.1 µm, 10 mm, 50/Pk - 6809-3012

    Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. Low-binding aluminum oxide provides sterile-grade retention with high recovery while handling aqueous and solvent samples cleanly and pulls liquid the membrane's full depth at once. The polypropylene housing presses snugly against the membrane during the pass and sheds virtually no extractable material into the sample. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Prefiltration

    • Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
    • Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
    • Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
    • Glass microfiber prefilter shields the downstream membrane from bulk particulate

    Membrane Characteristics

    • Rigid inorganic structure withstands high temperatures with minimal extractables
    • Absolute pore-size rating holds consistent across every protocol
    • Inorganic ceramic structure resists solvent swelling common to polymer membrane materials
    • Chemical stability in aqueous solutions spans a pH 3 to 9 range
    • Membrane surface turns optically transparent once wetted with liquid

    Housing Characteristics

    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation

    A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Upstream sample clarification keeps your separations clean and reproducible so your filtrate reaches the column clean. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    6.2 bar (90 psi)
    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Anopore (Aluminum Oxide)
    Diameter
    10mm
    Filtration Area
    0.78cm²
    Holdup Volume
    <20µl
    Material
    Anopore
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    40°C
    Pack Count
    50
    Pore Size (µm)
    0.1
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Volume Throughput (ml)
    Up to 10ml
    Wettability
    Hydrophilic
    • Electrolyte Clarification - Removes colloidal particles from electrochemical solutions for reproducible impedance and conductivity measurements.
    • Drinking Water Compliance - Concentrates microorganisms from potable water samples for enumeration and regulatory-method pathogen detection testing.
    • Single-Particle Analysis - Concentrates nanoparticles from dilute suspensions for tunable resistive pulse sensing and nanoparticle tracking.
    • Gravimetric Solids Testing - Determine particulate mass accurately, using a non-hygroscopic ceramic that resists moisture-driven drift.
    • Multiplex Bead Assay Prep - Clears immunoassay sample matrices of residual debris that would cause carryover interference between bead populations.
    • Drug Nanoparticle QC - Removes oversized aggregates from nanoparticle drug carriers before size and zeta potential analysis for formulation release.