Whatman Anotop Aluminum Oxide Syringe Filters, 0.2 µm, 10 mm, 50/Pk - 6809-3022
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. The alumina matrix presents a mineral oxide surface, not an organic polymer while providing sterile-grade retention with high recovery and becomes transparent in liquid after wetting. The polypropylene housing holds its seal true run after run and resists degradation from routine sample matrices. When sample preparation calls for a sterile filtrate at the point of injection, sterilizing-grade absolute retention delivers it directly, protecting the analytical method from microbial interference.
Prefiltration
- Glass microfiber prefilter shields the downstream membrane from bulk particulate
- Glass microfiber depth media loads particulate across its full thickness
- High dirt-holding capacity extends usable throughput by delaying membrane clogging
- Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
Membrane Characteristics
- Rigid inorganic structure withstands high temperatures with minimal extractables
- Mineral oxide chemistry gives proteins little to adsorb onto
- Chemical stability in aqueous solutions spans a pH 3 to 9 range
- Inorganic ceramic structure resists solvent swelling common to polymer membrane materials
- Naturally hydrophilic ceramic surface wets without pre-wetting in aqueous samples
Housing Characteristics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- The seal formed against the membrane blocks bypass at rated operating pressure
Fine particulates that slip through raise your system backpressure and bring maintenance forward. Upstream buffer clarification keeps your run from stalling on particulates that slipped through across routine and validated analytical methods. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.2 bar (90 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 10mm
- Filtration Area
- 0.78cm²
- Holdup Volume
- <20µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophilic
- Biopharmaceutical Clarification - Filters bioprocess buffers and excipient solutions to meet the lowest achievable particulate specifications.
- Fluorescence Spectroscopy Prep - Removes scattering particles from chromophore solutions for clean emission spectra in cuvette measurements.
- Geochemical Water Analysis - Filters water and soil leachates to resolve the dissolved fraction for ICP-MS and atomic spectroscopy quantitation.
- Electrolyte Clarification - Removes colloidal particles from electrochemical solutions for reproducible impedance and conductivity measurements.
- Nucleic Acid Clarification - Removes particulates from plasmid and oligonucleotide preparations ahead of gel electrophoresis and UV quantitation.
- Single-Particle Analysis - Concentrates nanoparticles from dilute suspensions for tunable resistive pulse sensing and nanoparticle tracking.