Whatman Anotop Aluminum Oxide Syringe Filters, 0.02 µm, 10 mm, 50/Pk - 6809-3102
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. The nanoporous Anotop surface slows early bacterial colonization compared to a smooth surface while tolerating high temperatures and broad solvent ranges and turns optically clear once wetted with liquid. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while arriving pre-sterilized and individually wrapped for aseptic sample preparation and routes flow to minimize backpressure in service. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Prefiltration
- Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
- High dirt-holding capacity extends usable throughput by delaying membrane clogging
- Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
- Glass microfiber depth media loads particulate across its full thickness
Membrane Characteristics
- Membrane surface turns optically transparent once wetted with liquid
- Anodized alumina matrix contains no monomers, plasticizers, adhesives, or wetting agents
- Chemical stability in aqueous solutions spans a pH 3 to 9 range
- Inorganic ceramic structure resists solvent swelling common to polymer membrane materials
- Extractable content stays minimal without interfering with downstream detection
Housing Characteristics
- Resists stress cracking from aqueous salt and buffer solutions
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Polypropylene housing tolerates ethylene oxide gas sterilization cycles without softening or dimensional distortion
- Rigid polypropylene body maintains its geometry through routine filtration pressure
Unfiltered particulates shift your retention times and peak shapes from run to run. Upstream sample clarification keeps your separations clean and reproducible so your filtrate reaches the column clean. Request Whatman's lot documentation and performance history to support your protocol validation.
Sterilization Guidance
The device arrives factory sterile and is intended for single-use sample preparation.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.9 bar (100 psi)
- Connection Type
- Luer-Lok/ Luer Slip
- Diameter
- 10mm
- Filtration Area
- 0.79cm²
- Material
- Anopore
- Pack Count
- 50
- Pore Size (µm)
- 0.02
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophilic
- Multiplex Bead Assay Prep - Clears immunoassay sample matrices of residual debris that would cause carryover interference between bead populations.
- Small Volume CE - Filter tiny sample volumes for capillary electrophoresis, minimizing hold-up volume to conserve valuable sample material.
- Carbohydrate Prep - Prepare saccharide samples for analysis, ensuring no organic extractables interfere with sensitive carbohydrate detection.
- Drinking Water Compliance - Concentrates microorganisms from potable water samples for enumeration and regulatory-method pathogen detection testing.
- Nucleic Acid Clarification - Removes particulates from plasmid and oligonucleotide preparations ahead of gel electrophoresis and UV quantitation.
- Cold Sterilization - Sterilize heat-sensitive additives safely, using 0.02 µm pores to remove bacteria without degrading critical components.