Whatman Anotop Aluminum Oxide Syringe Filters, 0.1 µm, 25 mm, 50/Pk - 6809-4012
Whatman's Anotop line separates by physical particle dimension alone, a capability rooted in ceramic media chemistry rather than the organic polymer chemistries used in most other membrane technologies. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Anotop's ceramic membrane becomes visibly clear the moment it is wetted and holds a uniform capillary pore array. Polyolefin construction sheds virtually no extractable material into the sample and maintains a low-dead-volume internal flow path. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Prefiltration
- Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
- Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
- Glass microfiber depth media loads particulate across its full thickness
- Glass microfiber prefilter shields the downstream membrane from bulk particulate
Membrane Characteristics
- Rigid inorganic structure withstands high temperatures with minimal extractables
- Absolute pore-size rating holds consistent across every protocol
- Anodized alumina matrix contains no monomers, plasticizers, adhesives, or wetting agents
- Uniform capillary pore array gives high pore density without lateral crossover
- Membrane surface turns optically transparent once wetted with liquid
Housing Characteristics
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
- Stable across the full aqueous pH range in routine sample work
- Thermal-bonded construction keeps adhesives out of the fluid path
Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request Whatman's performance credentials before you commit to a filtration standard requiring documented quality.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 6.2 bar (90 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Anopore (Aluminum Oxide)
- Diameter
- 25mm
- Filtration Area
- 4.15cm²
- Holdup Volume
- <150µl
- Material
- Anopore
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 40°C
- Pack Count
- 50
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Nucleic Acid Clarification - Removes particulates from plasmid and oligonucleotide preparations ahead of gel electrophoresis and UV quantitation.
- NMR Sample Filtration - Delivers aggregate-free aqueous filtrates with no organic extractables interfering with proton or carbon NMR spectra.
- Biopharmaceutical Clarification - Filters bioprocess buffers and excipient solutions to meet the lowest achievable particulate specifications.
- Membrane Protein Research - Filters detergent-solubilized protein preparations to remove insoluble aggregates before crystallography and cryo-EM.
- Gravimetric Solids Testing - Determine particulate mass accurately, using a non-hygroscopic ceramic that resists moisture-driven drift.
- HPLC Solvent Filtration - Filter chromatography mobile phases and solvents reliably, resisting degradation from aggressive organic reagents.