Chat with us, powered by LiveChat

Secure Checkout
GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.45um (150 pcs)

Thumbnail Filmstrip of GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.45um (150 pcs) Images

    Purchase GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.45um (150 pcs)

    GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.45um (150 pcs)
    Whatman SKU: 6870-2504

    $646.99
    Ships in 4 business days
     

    Whatman GD/X Nylon Syringe Filters, 0.45 µm, 25 mm, 150/Pk - 6870-2504

    Whatman fits more prefiltration capacity into the GD/X housing without enlarging it, a space-efficient answer for samples too demanding for one filtration pass. Syringe filters span a wide range of membrane chemistries and pore sizes, so the format can be matched to the sample matrix and solvent system in use. Nylon wets on contact with aqueous samples while fitting routine analytical sample preparation and screens out particles wider than the membrane's rated diameter. The polypropylene housing routes flow to minimize backpressure in service while shedding virtually no extractable material into the sample and resists degradation from routine sample matrices. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Prefiltration

    • Glass microfiber prefilter shields the downstream membrane from bulk particulate
    • High dirt-holding capacity extends usable throughput by delaying membrane clogging
    • Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
    • Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane

    Membrane Characteristics

    • Solvent compatibility extends to both acetonitrile and methanol
    • Ester- and alcohol-resistant across common laboratory sample preparations
    • Non-sterile format suits HPLC and GC sample clarification
    • Alkaline-resistant across a broad range of aqueous buffers
    • Common ketone solvents, including acetone, methyl ethyl ketone, and methyl isobutyl ketone, cause no attack

    Housing Characteristics

    • The seal formed against the membrane blocks bypass at rated operating pressure
    • PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    2.0 bar (29 psi)
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    25mm
    Filtration Area
    4.6cm²
    Flow Rate
    29
    Holdup Volume
    1.4ml
    Material
    Nylon
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    150
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    Glass Microfiber (GMF)
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Fermentation Monitoring - Clarifies samples from microbial fermentation for rapid analyte measurement of glucose, ethanol, and metabolite levels.
    • Cosmetics Batch Testing - Filters aqueous lotions, serums, and personal care products for particulate QC and potency assay sampling.
    • QuEChERS Cleanup - Clarifies acetonitrile food extracts after dispersive cleanup, protecting GC-MS and LC-MS systems during pesticide screening.
    • GC Sample Prep - Clarifies aqueous and organic extracts ahead of gas chromatography injection, protecting inlets from particulate fouling.
    • Content Uniformity Testing - Removes insoluble excipient and binder particulates that would skew spectrophotometric or HPLC potency-assay results.
    • Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.

    Related Products