Chat with us, powered by LiveChat

Secure Checkout
GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.2um (1500 pcs)

Thumbnail Filmstrip of GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.2um (1500 pcs) Images

    Purchase GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.2um (1500 pcs)

    GD/X 25mm Syringe Filter, Nylon Filteration Medium, 0.2um (1500 pcs)
    Whatman SKU: 6871-2502

    $3,273.99
    Ships in 4 business days
     

    Whatman GD/X Nylon Syringe Filters, 0.2 µm, 25 mm, 1500/Pk - 6871-2502

    Whatman pairs a borosilicate fiber depth layer with the finishing membrane inside every GD/X unit, a construction meant to process loads heavy enough to clog a conventional one-stage filter. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. Nylon wets on contact with aqueous samples and stays stable across pH 3 to 12. The polypropylene housing holds its seal true run after run while holding its form through high-temperature sample preparation conditions and stays inert across common laboratory solvents. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Autoclaving at 121°C for 30 minutes leaves pore structure intact
    • Synthetic polyamide backbone resists microbial and enzymatic degradation unlike cellulose membranes
    • Moisture-plasticized amide linkages raise membrane impact toughness over dry resin
    • Alkaline-resistant across a broad range of aqueous buffers
    • Common ketone solvents, including acetone, methyl ethyl ketone, and methyl isobutyl ketone, cause no attack

    Housing Characteristics

    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Housing retains dimensional stability and seal integrity through elevated-temperature operation up to 121°C.
    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping

    Removing particulates from your buffers and mobile phases extends column life and keeps your baselines steady. Upstream buffer clarification keeps avoidable particulates out of your flow path while keeping the filtrate analytically clean. Contact Tisch Scientific for technical guidance on selecting the right filtration product for your specific application requirements.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    2.9 bar (42 psi)
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    25mm
    Filtration Area
    4.6cm²
    Flow Rate
    46
    Holdup Volume
    1.4ml
    Material
    Nylon
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    150
    Pore Size (µm)
    0.2
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    Glass Microfiber (GMF)
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Drinking Water Analysis - Clarifies tap and source water samples ahead of metals, nitrate, and trace-contaminant compliance testing.
    • Cosmetics Batch Testing - Filters aqueous lotions, serums, and personal care products for particulate QC and potency assay sampling.
    • Beverage QC Clarification - Clarifies wine, beer, and juice samples ahead of analytical and microbiological testing in quality control labs.
    • Tissue Homogenate Prep - Pairs a glass-fiber prefilter with a nylon final membrane to clarify particulate-heavy tissue homogenates for analysis.
    • QuEChERS Cleanup - Clarifies acetonitrile food extracts after dispersive cleanup, protecting GC-MS and LC-MS systems during pesticide screening.
    • Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.