Chat with us, powered by LiveChat

Secure Checkout
GD/X 13mm Syringe Filter, PTFE Filteration Medium, 0.45um (1500 pcs)

Thumbnail Filmstrip of GD/X 13mm Syringe Filter, PTFE Filteration Medium, 0.45um (1500 pcs) Images

    Purchase GD/X 13mm Syringe Filter, PTFE Filteration Medium, 0.45um (1500 pcs)

    GD/X 13mm Syringe Filter, PTFE Filteration Medium, 0.45um (1500 pcs)
    Whatman SKU: 6875-1304

    $2,920.99
    Ships in 7 weeks
     

    Whatman GD/X PTFE Syringe Filters, 0.45 µm, 13 mm, 1500/Pk - 6875-1304

    Whatman ties GD/X prefiltration performance to one closely held fiber-grade standard applied at every production run, keeping results repeatable from one manufacturing lot to the next. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration never delays the next analyst's run waiting on a shared holder. PTFE filters aggressive organic solvents without swelling or breakdown while suiting gas, vent, and solvent-stream filtration and clarifies solvent streams at the rated pore size. The polypropylene housing routes flow to minimize backpressure in service while sustaining structural integrity through elevated-temperature filtration operations and presses snugly against the membrane during the pass. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.

    Membrane Characteristics

    • Inert composition offers no nutrient source for microbial growth
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • High porosity minimizes hold-up volume for small sample volumes
    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Stable across a wide operating temperature range for demanding methods

    Housing Characteristics

    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure.
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Rigid polypropylene body maintains its geometry through routine filtration pressure

    Filtering aggressive solvents and reagents through a filter that holds up to the chemistry keeps your sample prep reliable. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request Whatman's lot documentation and performance history to support your protocol validation.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    0.6 bar (9 psi) [IPA]
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    13mm
    Filtration Area
    1.3cm²
    Holdup Volume
    0.5ml
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    150
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    Glass Microfiber (GMF)
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 10ml
    Wettability
    Hydrophobic
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
    • Environmental Prep - Clears heavy particulate loads from solvent-based soil and sediment extracts, pairing a glass prefilter with a PTFE membrane.
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • QuEChERS Extract Cleanup - Clears matrix debris from acetonitrile-based pesticide extracts with a glass prefilter ahead of LC-MS/MS analysis.