Whatman GD/X Polyethersulfone (PES) Syringe Filters, 0.2 µm, 25 mm, 150/Pk - 6876-2502
Whatman places a fibrous glass mat before the final membrane in every GD/X device, clearing a turbid sample in one pass through the same housing. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. PES stays stable across the full pH 1 to 14 range and screens out bacteria before they cross its finest pore rating. Polyolefin construction sheds virtually no extractable material into the sample while pressing snugly against the membrane during the pass and routes flow to minimize backpressure in service. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Prefiltration
- Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
- Glass microfiber depth media loads particulate across its full thickness
- Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
- Glass microfiber prefilter shields the downstream membrane from bulk particulate
Membrane Characteristics
- DNA and RNA pass through with negligible adsorptive loss
- Sulfone backbone's hydrolytic stability tolerates repeated autoclave steam sterilization cycles
- Ionic extractables from the membrane stay very low
- Antibody and protein samples pass through PES with minimal adsorptive loss
- Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Stable across the full aqueous pH range in routine sample work
A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Request Whatman's lot documentation and performance history to support your protocol validation.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 3.4 bar (50 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 46
- Holdup Volume
- 1.4ml
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 150
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Glass Microfiber (GMF)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Content Uniformity - Clarifies dense pharmaceutical samples easily, ensuring consistent results in uniformity testing without filter blockage.
- Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
- Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
- Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
- Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
- PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.