    Whatman GD/X Cellulose Acetate (CA) Syringe Filters, 0.2 µm, 25 mm, 150/Pk - 6880-2502

    Whatman pairs a borosilicate fiber depth layer with the finishing membrane inside every GD/X unit, a construction meant to process loads heavy enough to clog a conventional one-stage filter. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Cellulose acetate binds less protein than mixed cellulose ester of similar pore size while intercepting bacteria before they cross its smallest rating and stays stable across pH 4 to 8. Polypropylene construction maintains a low-dead-volume internal flow path while staying inert across common laboratory solvents and leaves no seam for sample to bypass the membrane. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.

    Prefiltration

    • Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
    • Glass microfiber depth media loads particulate across its full thickness
    • Glass microfiber prefilter shields the downstream membrane from bulk particulate
    • High dirt-holding capacity extends usable throughput by delaying membrane clogging

    Membrane Characteristics

    • Retains particles at the membrane surface instead of throughout its thickness
    • Biologically nontoxic cellulose ester provides a clean filtration surface
    • No alcohol pre-wetting required before aqueous sample introduction
    • Cellulose ester backbone stable across aqueous pH range of 4 to 8
    • Minimal non-specific adsorption of analytes at the membrane surface

    Housing Characteristics

    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Thermal-bonded construction keeps adhesives out of the fluid path

    An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Upstream buffer clarification keeps your run from stalling on particulates that slipped through across routine and validated analytical methods. Request a quote on Whatman filtration products from the Tisch Scientific team.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    3.4 bar (50 psi)
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    25mm
    Filtration Area
    4.6cm²
    Flow Rate
    46
    Holdup Volume
    1.4ml
    Material
    Cellulose Acetate
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    150
    Pore Size (µm)
    0.2
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    Glass Microfiber (GMF)
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Temperature Stability - Maintains integrity across normal lab bench temperatures for consistent, dependable filtration performance.
    • Clinical Chemistry Prep - Clarifies turbid or lipemic serum and plasma samples ahead of loading onto automated clinical chemistry analyzers.
    • Alcohol Compatibility - Handles low molecular weight alcohols reliably, supporting specialized chemical clarification tasks in the laboratory.
    • Saline Solution Prep - CA membrane filters saline and physiological buffer solutions, removing particulates for in vitro assays and formulation use.
    • TOC Sample Prep - Hydrophilic CA removes particles from water samples with minimal carbon contribution, protecting total organic carbon measurement.
    • Dissolution Testing - Clarifies drug-release samples of undissolved particulates pulled from dissolution vessels, ensuring accurate potency results.