Whatman GD/X Regenerated Cellulose (RC) Syringe Filters, 0.45 µm, 25 mm, 150/Pk - 6882-2504
Whatman fits more prefiltration capacity into the GD/X housing without enlarging it, a space-efficient answer for samples too demanding for one filtration pass. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. Natural cellulose chemistry lets protein and analyte reach the injection vial intact while handling acetonitrile, methanol, acetone, and DMSO during sample prep and clarifies particulates at the rated pore size for clean injections. The PP housing sustains full structural integrity during elevated-temperature filtration operations and holds its seal true run after run. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Prefiltration
- Glass microfiber depth media loads particulate across its full thickness
- Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
- Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
- Glass microfiber prefilter shields the downstream membrane from bulk particulate
Membrane Characteristics
- Reduces background noise in UV-Vis spectrophotometry by removing light-scattering particulates
- Naturally hydrophilic surface wets without pre-wetting in aqueous and solvent samples
- Stable across the pH 3 to 12 operating range without degradation of pore structure
- Compatible with the full solvent range used in reversed-phase and normal-phase HPLC
- Analyte recovery from biological matrices stays high due to reduced membrane surface adsorption
Housing Characteristics
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Stable across the full aqueous pH range in routine sample work
- PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing
- Minimal extractable release from the housing supports sensitive analytical work downstream
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 2.8 bar (41 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 21
- Holdup Volume
- 1.4ml
- Material
- Regenerated Cellulose
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 150
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Glass Microfiber (GMF)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- IC Sample Prep - Clarifies aqueous samples ahead of ion chromatography, protecting IC guard columns from particulate fouling between injections.
- Broad Solvent Compatibility - Delivers broad compatibility with DMSO and other solvents common in drug discovery pipelines.
- Cannabis Potency Testing - Clarifies cannabis extracts with low nonspecific binding, supporting accurate THC and CBD potency quantification results.
- Protein Sample Prep - Low non-specific binding preserves enzyme and receptor concentrations when clarifying aqueous protein solutions for bioassays.
- HPLC Analysis - Minimizes extractables in critical HPLC sample preparation, ensuring cleaner chromatograms and accurate data generation.
- Buffer Prep - Low extractables and a hydrophilic surface make RC filters ideal for clarifying pharmaceutical buffers and aqueous reagents in the lab.