    Whatman GD/X Glass Fiber (GF) Syringe Filters, 1.6 µm, 25 mm, 150/Pk - 6883-2516

    Whatman stages multiple glass fiber layers inside the GD/X cartridge to intercept particles in progressive steps, leaving only the smallest fraction to reach the tightly rated final membrane. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. The borosilicate glass matrix resists chemical attack across diverse solvents and accepts water-based samples on contact. The polypropylene housing routes flow to minimize backpressure in service while leaving no seam for sample to bypass the membrane and sheds virtually no extractable material into the sample. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • Biologically inert borosilicate fiber with broad chemical compatibility
    • Continuous glass fiber microstructure supports even flow distribution across the filter face
    • Inorganic fiber composition resists biodegradation during extended holding or room-temperature storage
    • Resists adsorptive interaction with most common laboratory solvents and reagents
    • Inorganic construction suits demanding sample-preparation chemistries

    Housing Characteristics

    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Optimized internal geometry minimizes backpressure in service
    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Glass Microfiber (Binder Free)
    Diameter
    25mm
    Filtration Area
    4.91cm²
    Flow Rate
    Fast
    Material
    Glass Micro Fiber
    Maximum Operating Temperature (°C)
    550°C
    Membrane Thickness (µm)
    260µm
    Pack Count
    150
    Pore Size (µm)
    1.6
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 500°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Crude Oil Prep - Glass fiber removes wax and asphaltene particulates from crude oil samples ahead of elemental and composition analysis.
    • Coatings Quality Testing - Glass fiber's chemical inertness handles viscous, solvent-laden coating formulations without swelling or degrading.
    • Pre-filtration - Acts as a robust depth filter that protects downstream membranes, significantly extending final filtration service life.
    • Suspension Culture - Depth filtration structure keeps shear stress low during harvest clarification, limiting cell lysis and contaminant release.
    • Air Sampling Extract Prep - Glass fiber removes insoluble particulates from air filter extracts ahead of metals and organic compound analysis.
    • TOC Sample Filtration - Glass fiber prefilters aqueous samples ahead of total organic carbon analysis, removing particles without adding carbon.