Chat with us, powered by LiveChat

Secure Checkout
GD/X 13mm Syringe Filter, Glass Microfiber GF/B Filteration Medium, 1.0um (150 pcs)

Thumbnail Filmstrip of GD/X 13mm Syringe Filter, Glass Microfiber GF/B Filteration Medium, 1.0um (150 pcs) Images

    Purchase GD/X 13mm Syringe Filter, Glass Microfiber GF/B Filteration Medium, 1.0um (150 pcs)

    GD/X 13mm Syringe Filter, Glass Microfiber GF/B Filteration Medium, 1.0um (150 pcs)
    Whatman SKU: 6884-1310

    $487.95
    Ships in 10 business days
     

    Whatman GD/X Glass Fiber (GF) Syringe Filters, 1 µm, 13 mm, 150/Pk - 6884-1310

    Whatman places a fibrous glass mat before the final membrane in every GD/X device, clearing a turbid sample in one pass through the same housing. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. Glass fiber captures particulates throughout its depth for high loading capacity while accepting water-based samples on contact and stays biologically inert across diverse chemistries. Polypropylene construction maintains a low-dead-volume internal flow path while standing firm against aqueous acids, bases, and alcohols during regular handling and leaves no seam for sample to bypass the membrane. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Randomly oriented fiber network creates multiple particle interception paths
    • Extends filterable sample volume three to seven times versus unprotected media
    • Fiber matrix sustains throughput as particulate load builds within the filter depth
    • Surface silanol groups attract water molecules for immediate aqueous wetting
    • Dimensionally stable fiber mat resists compaction under sustained backpressure or vacuum

    Housing Characteristics

    • Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Plasticizer-free polyolefin construction keeps the fluid path clean

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Glass Microfiber (Binder Free)
    Diameter
    13mm
    Filtration Area
    1.33cm²
    Flow Rate
    Fast
    Material
    Glass Micro Fiber
    Maximum Operating Temperature (°C)
    550°C
    Membrane Thickness (µm)
    675µm
    Pack Count
    150
    Pore Size (µm)
    1
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 500°C
    Volume Throughput (ml)
    Up to 10ml
    Wettability
    Hydrophilic
    • Coatings Quality Testing - Glass fiber's chemical inertness handles viscous, solvent-laden coating formulations without swelling or degrading.
    • TOC Sample Filtration - Glass fiber prefilters aqueous samples ahead of total organic carbon analysis, removing particles without adding carbon.
    • Urine Sample Prep - Glass fiber removes urinary sediment and mucus from urine samples ahead of HPLC and immunoassay clinical testing.
    • Cannabis Extract Analysis - Glass fiber removes lipid and plant wax particulates from cannabis extracts ahead of cannabinoid potency testing.
    • Geological Sample Prep - High dirt-loading capacity across two glass stages processes heavily loaded environmental extracts without early clogging.
    • Milk and Dairy Analysis - Glass fiber prefiltration removes casein and fat globules from dairy samples ahead of HPLC and ion chromatography.