    Whatman GD/X Glass Fiber (GF) Syringe Filters, 1.5 µm, 25 mm, 150/Pk - 6892-2515

    Whatman places a fibrous glass mat before the final membrane in every GD/X device, clearing a turbid sample in one pass through the same housing. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The glass microfiber matrix accepts water-based samples on contact and captures particulates throughout its depth. The PP housing sustains full structural integrity during elevated-temperature filtration operations while leaving no seam for sample to bypass the membrane and maintains a low-dead-volume internal flow path. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • Handles acidic, neutral, and mildly alkaline aqueous samples without matrix degradation
    • Fiber matrix sustains throughput as particulate load builds within the filter depth
    • Silanol groups on borosilicate fiber surfaces provide inherent chemical reactivity
    • High dirt-loading capacity extends filterable sample volume on turbid, particle-laden samples
    • High internal surface area supports broad particle interception throughout fiber depth

    Housing Characteristics

    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Resists stress cracking from aqueous salt and buffer solutions
    • PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Glass Microfiber (Binder Free)
    Diameter
    25mm
    Filtration Area
    4.91cm²
    Flow Rate
    Fast
    Material
    Glass Microfiber (934-AH)
    Membrane Thickness (µm)
    435µm
    Pack Count
    150
    Pore Size (µm)
    1.5
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 500°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophilic
    • Suspension Culture - Depth filtration structure keeps shear stress low during harvest clarification, limiting cell lysis and contaminant release.
    • Heavy Metal Digests - Glass fiber removes undissolved particulates from acid-digested soil and water samples ahead of ICP and AAS analysis.
    • Industrial Polymer Prep - Glass fiber removes polymer particulates and precipitates from solvent solutions ahead of GPC and rheology analysis.
    • Urine Sample Prep - Glass fiber removes urinary sediment and mucus from urine samples ahead of HPLC and immunoassay clinical testing.
    • Catalyst Sample Testing - Glass fiber removes fine catalyst particles from reaction product streams ahead of compositional and yield analysis.
    • Dissolution Testing - Clarifies pharmaceutical dissolution media of excipient particulates, protecting HPLC and UV assay systems from column fouling.