Whatman GD/X Polyethersulfone (PES) Syringe Filters, 0.2 µm, 25 mm, 150/Pk - 6905-2502
Whatman fits more prefiltration capacity into the GD/X housing without enlarging it, a space-efficient answer for samples too demanding for one filtration pass. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. The PES matrix tolerates aliphatic alcohols, glycols, and aqueous buffers while admitting aqueous reagents on contact, skipping any surfactant rinse and screens out bacteria before they cross its finest pore rating. Polypropylene construction resists chemical degradation from routine sample matrices while holding its form through high-temperature sample preparation conditions and maintains a low-dead-volume internal flow path. When sample preparation calls for a sterile filtrate at the point of injection, sterilizing-grade absolute retention delivers it directly, protecting the analytical method from microbial interference.
Prefiltration
- High dirt-holding capacity extends usable throughput by delaying membrane clogging
- Glass microfiber prefilter shields the downstream membrane from bulk particulate
- Glass microfiber depth media loads particulate across its full thickness
- Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
Membrane Characteristics
- Non-hydrogen-bonding surface avoids the polar adsorption nylon's amide backbone causes
- Sterilizing-grade PES membrane lots are challenge-tested against Brevundimonas diminuta to qualify 0.2 micron retention
- Absolute pore size rating holds consistent across every lot
- Ionic extractables from the membrane stay very low
- Antibody and protein samples pass through PES with minimal adsorptive loss
Housing Characteristics
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 3.4 bar (50 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 46
- Holdup Volume
- 1.4ml
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 150
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Glass Microfiber (GMF)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.
- Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
- Content Uniformity - Clarifies dense pharmaceutical samples easily, ensuring consistent results in uniformity testing without filter blockage.
- Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
- Tissue Processing - Prepares biological tissue homogenates smoothly, managing high protein and cellular debris for cleaner downstream analysis.
- Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.