Whatman GD/XP Nylon Syringe Filters, 0.45 µm, 25 mm, 150/Pk - 6971-2504
Whatman ties GD/XP prefiltration performance to one closely held polypropylene specification applied at every production run, keeping ion-clean results repeatable from lot to lot. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. Nylon stays stable across pH 3 to 12 while resisting particle shedding across the run and supports high-volume routine filtration. Polypropylene construction maintains a low-dead-volume internal flow path and sustains its dimensional form through high-temperature filtration workflows. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Prefiltration
- High dirt-holding capacity sustains flow through turbid, viscous, particle-laden samples
- Nonwoven polypropylene matrix captures coarse particulate through its depth
- Polypropylene prefilter resists acids, bases, and common organic solvents
- Low pressure drop across the depth layer supports higher-throughput processing
Membrane Characteristics
- Synthetic polyamide backbone resists microbial and enzymatic degradation unlike cellulose membranes
- Compatible with most HPLC mobile phases for sample clarification
- Ester- and alcohol-resistant across common laboratory sample preparations
- Autoclaving at 121°C for 30 minutes leaves pore structure intact
- Polar amide backbone gives high native affinity for nucleic acids
Housing Characteristics
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
- Medical-grade polypropylene with broad chemical compatibility
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Plasticizer-free polyolefin construction keeps the fluid path clean
Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 2.0 bar (29 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Holdup Volume
- 1.4ml
- Material
- Nylon
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 150
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Polypropylene (10µm + 5µm)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.
- QuEChERS Cleanup - Clarifies acetonitrile food extracts after dispersive cleanup, protecting GC-MS and LC-MS systems during pesticide screening.
- Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.
- Drinking Water Analysis - Clarifies tap and source water samples ahead of metals, nitrate, and trace-contaminant compliance testing.
- Forensic Toxicology Screening - Clarifies urine and blood extracts ahead of LC-MS or GC-MS analysis in forensic drug-screening laboratories.
- Biofuel Particulate Testing - Removes particulate debris from biodiesel and fuel samples ahead of chromatographic QC analysis in fuel testing labs.