Whatman GD/XP Polypropylene (PP) Syringe Filters, 0.45 µm, 25 mm, 150/Pk - 6993-2504
GD/XP swaps the glass fiber prefilter for layered polypropylene inside the same compact housing, keeping ion backgrounds low for samples headed to ICP-OES or ICP-MS. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. The hydrophobic polypropylene matrix repels water in vent and solvent service and resists a broad range of organic solvents, acids, and bases. Polyolefin construction sheds virtually no extractable material into the sample while maintaining dimensional stability through sample runs at temperatures up to 121°C and routes flow to minimize backpressure in service. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.
Prefiltration
- Nonwoven polypropylene matrix captures coarse particulate through its depth
- High dirt-holding capacity sustains flow through turbid, viscous, particle-laden samples
- Low pressure drop across the depth layer supports higher-throughput processing
- Polypropylene prefilter resists acids, bases, and common organic solvents
Membrane Characteristics
- Compatible with dilute acids, ketones, and aliphatic esters at room temperature
- Flexible polypropylene fiber matrix adapts to modest pressure cycles without fracture
- Broad solvent tolerance includes glycols, aliphatic alcohols, and dilute salt solutions
- Alcohol pre-wetting opens the hydrophobic matrix to aqueous sample streams
- Nominal depth matrix distributes particulate load progressively through the medium volume
Housing Characteristics
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Medical-grade polypropylene with broad chemical compatibility
- PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing
- Thermal-bonded construction keeps adhesives out of the fluid path
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- (Hydrophobic)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Holdup Volume
- 1.4ml
- Material
- Polypropylene Depth Filter (DpPP)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 150
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Polypropylene (10µm + 5µm)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophobic
- Strong Base Filtration - Resists dilute sodium hydroxide and potassium hydroxide solutions for alkaline extraction and titration sample preparation.
- Injector Port Protection - Removes cell debris and protein precipitates before injection, guarding HPLC and GC autosampler needles from wear.
- Industrial Solvent Monitoring - Clarifies organic solvent process streams and used-solvent recovery batches for quality and contamination analysis.
- Mining Acid Leachate Analysis - Processes dilute sulfuric acid mine drainage and leachate samples for dissolved metal and ion speciation analysis.
- Biofuel Ethanol Analysis - Clarifies fuel ethanol and blended biofuel samples ahead of GC and refractometric purity and water content testing.
- Hormone and Steroid Testing - Handles alcohol and acetonitrile steroid extraction matrices for HPLC-MS confirmation in pharmaceutical QC labs.