Whatman Puradisc Cellulose Acetate (CA) Syringe Filters, 0.2 µm, 30 mm, 50/Pk - 10462205
Whatman maintains in-house specialists who set and verify material specifications separately for its cellulose, glass-fiber, and polymer membrane chemistries, tailoring quality control to how each one behaves in use. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Cellulose acetate handles water-based samples and low-alcohol solutions while relying on hydroxyl chemistry alone, no coating needed and stays smooth with low extractable background. The polycarbonate housing stands up to rugged field and bench handling while holding its form under elevated process pressure and suits aqueous samples, buffers, and reagents. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Retains particles at the membrane surface instead of throughout its thickness
- No alcohol pre-wetting required before aqueous sample introduction
- Smooth membrane face with even pore distribution across the active filtration area
- Tolerates methanol and ethanol at typical laboratory working concentrations
- Naturally hydrophilic surface wets readily with aqueous samples
Housing Characteristics
- Impact toughness holds through cold-chain storage and refrigerated sample handling
- Polycarbonate construction remains stable through prolonged aqueous immersion at ambient temperature
- Creep resistance keeps the polycarbonate housing seal secure under sustained mechanical load
- Low moisture uptake keeps housing dimensions stable through prolonged aqueous contact
An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request Whatman's lot documentation and performance history to support your protocol validation.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 3.4 bar (50 psi)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polycarbonate
- Diameter
- 30mm
- Filtration Area
- 5.7cm²
- Holdup Volume
- <50µl
- Material
- Cellulose Acetate
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 50
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 150ml
- Wettability
- Hydrophilic
- Low-Volume Sample Prep - CA syringe filters process precious microliter samples with minimal hold-up volume, maximizing recovery of dilute analytes.
- Cell Culture Filtration - CA membrane clarifies conditioned media and aqueous culture supplements without stripping nutrients or growth factors.
- Aqueous Sample Prep - CA membrane clarifies water-based samples quickly without pre-wetting, protecting downstream instruments from particle fouling.
- UV Spectroscopy Prep - CA's naturally hydrophilic, low-binding surface avoids analyte loss during sensitive UV-Vis sample prep work.
- Stability Testing Prep - Hydrophilic CA membrane clarifies stability samples without analyte loss, supporting accurate potency tracking over time.
- Ophthalmic Formulation Prep - Low-extractable CA filters ophthalmic solutions ahead of quality testing and release without contributing contaminants.