Chat with us, powered by LiveChat

Secure Checkout
Pura Disc FP 30mm CA Syringe Filter, 1.2um, Sterile, 50 Pk

Thumbnail Filmstrip of Pura Disc FP 30mm CA Syringe Filter, 1.2um, Sterile, 50 Pk Images

    Purchase Pura Disc FP 30mm CA Syringe Filter, 1.2um, Sterile, 50 Pk

    Pura Disc FP 30mm CA Syringe Filter, 1.2um, Sterile, 50 Pk
    Whatman SKU: 10462260

    $204.95
    Ships in 4 business days
     

    Whatman Puradisc Cellulose Acetate (CA) Syringe Filters, 1.2 µm, 30 mm, 50/Pk - 10462260

    Whatman's filtration expertise, refined across a century-plus of disciplined manufacturing, has made its name synonymous with laboratory-grade quality worldwide. A syringe filter's small hold-up volume limits sample loss, a meaningful difference when working with a limited or precious sample. Cellulose acetate delivers absolute particle retention at rated size and takes up aqueous buffers on contact. The polycarbonate housing suits aqueous samples, buffers, and reagents in routine use while standing up to rugged field and bench handling and supports demanding high-pressure filtration. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • Native surface hydroxyl groups sustain a hydration layer ahead of protein contact
    • Minimal non-specific adsorption of analytes at the membrane surface
    • Cellulose ester backbone stable across aqueous pH range of 4 to 8
    • No alcohol pre-wetting required before aqueous sample introduction
    • Smooth membrane face with even pore distribution across the active filtration area

    Housing Characteristics

    • The polycarbonate housing seats the membrane disc repeatably with consistent edge contact
    • PC housing withstands dilute aqueous acid and base sample matrices at ambient conditions
    • Rigid construction holds dimensional tolerance under filtration load
    • Impact toughness holds through cold-chain storage and refrigerated sample handling

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Request Whatman's quality documentation to support your filtration step meeting a recognized laboratory-science standard.

    Sterilization Guidance

    The device arrives factory sterile and is intended for single-use sample preparation.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polycarbonate
    Diameter
    30mm
    Filtration Area
    5.7cm²
    Holdup Volume
    <50µl
    Material
    Cellulose Acetate
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    50
    Pore Size (µm)
    1.2
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 150ml
    Wettability
    Hydrophilic
    • Serum Protein Analysis - Low-binding CA ensures serum proteins pass through without adsorption, preserving sample integrity for immunoassay panels.
    • Urinalysis Prep - CA clarifies urine samples by removing particulates ahead of automated urinalysis without altering biochemical composition.
    • Protein Recovery - Maximizes yield of target proteins by minimizing nonspecific binding, preserving valuable biological samples.
    • Saline Solution Prep - CA membrane filters saline and physiological buffer solutions, removing particulates for in vitro assays and formulation use.
    • Amino Acid Analysis - Hydrophilic CA clarifies amino acid standards and digest samples for HPLC or ion chromatography quantitation of food and feeds.
    • IC Sample Prep - CA membrane clarifies aqueous samples before IC injection, protecting guard columns and extending column life without analyte loss.