Whatman Puradisc Cellulose Acetate (CA) Syringe Filters, 1.2 µm, 30 mm, 50/Pk - 10462261
Whatman verifies performance ratings at the lot level using process controls that stay uniform across its entire filtration lineup. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The cellulose acetate membrane clarifies particulates at the rated pore size while keeping filtrate clean ahead of analysis and relies on hydroxyl chemistry alone, no coating needed. The polycarbonate housing withstands impact and handling without cracking while supporting demanding high-pressure filtration and keeps its molded fit intact through demanding process runs. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.
Membrane Characteristics
- Stable in aqueous saline, buffer, and protein solution matrices
- Minimal non-specific adsorption of analytes at the membrane surface
- Cellulose ester backbone stable across aqueous pH range of 4 to 8
- Retains particles at the membrane surface instead of throughout its thickness
- Dilute samples retain their true, unadsorbed concentration through the membrane
Housing Characteristics
- Optically clear polycarbonate body keeps the sample visible through the pass
- Luer-compatible polycarbonate housing connects securely with standard syringe outlets for hand-pressure filtration
- Flexural rigidity resists housing collapse under vacuum-driven filtration
- Low moisture uptake keeps housing dimensions stable through prolonged aqueous contact
Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Request a quote on Whatman filtration products from the Tisch Scientific team.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polycarbonate
- Diameter
- 30mm
- Filtration Area
- 5.7cm²
- Holdup Volume
- <50µl
- Material
- Cellulose Acetate
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 50
- Pore Size (µm)
- 1.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 150ml
- Wettability
- Hydrophilic
- Urinalysis Prep - CA clarifies urine samples by removing particulates ahead of automated urinalysis without altering biochemical composition.
- TOC Sample Prep - Hydrophilic CA removes particles from water samples with minimal carbon contribution, protecting total organic carbon measurement.
- Aqueous Sample Prep - CA membrane clarifies water-based samples quickly without pre-wetting, protecting downstream instruments from particle fouling.
- PCR Sample Prep - CA's very low non-specific binding ensures nucleic acids and buffer components pass through cleanly ahead of PCR amplification.
- Serum Protein Analysis - Low-binding CA ensures serum proteins pass through without adsorption, preserving sample integrity for immunoassay panels.
- Cell Culture Filtration - CA membrane clarifies conditioned media and aqueous culture supplements without stripping nutrients or growth factors.