    Whatman Puradisc Cellulose Acetate (CA) Syringe Filters, 0.45 µm, 30 mm, 500/Pk - 10462600

    Whatman maintains in-house specialists who set and verify material specifications separately for its cellulose, glass-fiber, and polymer membrane chemistries, tailoring quality control to how each one behaves in use. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. Cellulose acetate's native hydroxyl groups attract a thin water layer to the membrane surface and keeps filtrate clean ahead of analysis. The polycarbonate housing stands up to rugged field and bench handling while suiting aqueous samples, buffers, and reagents in routine use and closes tightly enough that sample only exits through the membrane. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.

    Membrane Characteristics

    • Stable in aqueous saline, buffer, and protein solution matrices
    • Minimal non-specific adsorption of analytes at the membrane surface
    • BSA adsorption near 3.8 micrograms per square centimeter across the membrane
    • No alcohol pre-wetting required before aqueous sample introduction
    • Dilute samples retain their true, unadsorbed concentration through the membrane

    Housing Characteristics

    • Heat deflection temperature near 135°C gives the housing thermal headroom above typical aqueous filtration conditions
    • Impact toughness stays stable across a service temperature range from -40 to 120°C
    • Low moisture uptake keeps housing dimensions stable through prolonged aqueous contact
    • PC housing withstands dilute aqueous acid and base sample matrices at ambient conditions

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    2.0 bar (29 psi)
    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polycarbonate
    Diameter
    30mm
    Filtration Area
    5.7cm²
    Holdup Volume
    <50µl
    Material
    Cellulose Acetate
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    500
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 150ml
    Wettability
    Hydrophilic
    • Urinalysis Prep - CA clarifies urine samples by removing particulates ahead of automated urinalysis without altering biochemical composition.
    • CE Sample Prep - Delivers clean, particulate-free samples for capillary electrophoresis, safeguarding capillary integrity and run reproducibility.
    • Biological Solutions - Offers a stable, hydrophilic membrane for sensitive aqueous fluids, letting critical analytes pass through freely.
    • Clinical Chemistry Prep - Clarifies turbid or lipemic serum and plasma samples ahead of loading onto automated clinical chemistry analyzers.
    • Amino Acid Analysis - Hydrophilic CA clarifies amino acid standards and digest samples for HPLC or ion chromatography quantitation of food and feeds.
    • Allergen Testing Prep - CA's low-binding surface cleanly passes allergen proteins from aqueous food extracts ahead of ELISA allergen quantitation.