Whatman Puradisc PVDF Syringe Filters, 0.2 µm, 13 mm, 2000/Pk - 6765-1302
Whatman has built such a strong track record in published methods that laboratories default to citing its name in standardized protocols. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. PVDF holds up to alcohols and mild hydrocarbon solvents while shielding hydrophobic backbone from protein with surface modification and blocks bacterial passage through its smallest rated openings. Low-extractable polypropylene keeps sample purity intact through the filtration pass while sustaining efficient flow on viscous samples and holds its seal true run after run. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Membrane Characteristics
- Autoclave sterilization cycles leave pore structure and flow performance intact
- Intrinsic protein binding runs lower than nylon or mixed cellulose ester
- Low ionic extractables preserve baseline stability in conductivity-based ion chromatography detection
- Fluoropolymer chemistry resists microbial and fungal degradation
- Ethylene oxide sterilization cycles leave pore integrity and flow performance intact
Housing Characteristics
- Housing retains dimensional stability and seal integrity through elevated-temperature operation up to 121°C
- Optimized internal geometry minimizes backpressure in service
- Resists stress cracking from aqueous salt and buffer solutions
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Request Whatman's performance credentials before you commit to a filtration standard requiring documented quality.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 1.8 bar (26 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 13mm
- Filtration Area
- 1.3cm²
- Holdup Volume
- <25µl
- Material
- Polyvinylidene Difluoride (PVDF)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 2000
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophobic
- Microbiome Sampling - Concentrates waterborne microbial cells on a low-binding membrane ahead of DNA extraction and metagenomics sequencing.
- Water Quality Monitoring - Clarifies environmental and drinking water samples ahead of turbidity, ion, or contaminant testing in monitoring programs.
- IC Guard Filtration - Removes particulates from aqueous samples before ion analysis, keeping detector cells free of fouling between injections.
- Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
- Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
- QuEChERS Extract Prep - Removes co-extracted waxes and pigments from QuEChERS extracts, protecting GC-MS and LC-MS systems during pesticide testing.