Chat with us, powered by LiveChat

Secure Checkout
Pura Disc 13mm PES Syringe Filters, 0.45um, 500 Pk

Thumbnail Filmstrip of Pura Disc 13mm PES Syringe Filters, 0.45um, 500 Pk Images

    Purchase Pura Disc 13mm PES Syringe Filters, 0.45um, 500 Pk

    Pura Disc 13mm PES Syringe Filters, 0.45um, 500 Pk
    Whatman SKU: 6781-1304

    $1,306.95
    Ships in 10 business days
     

    Whatman Puradisc Polyethersulfone (PES) Syringe Filters, 0.45 µm, 13 mm, 500/Pk - 6781-1304

    Whatman verifies performance ratings at the lot level using process controls that stay uniform across its entire filtration lineup. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The PES membrane loads aqueous buffers with zero pre-wetting delay while staying stable across the pH 1 to 14 range and keeps that modified surface active throughout use. The polypropylene housing preserves sample chemistry across the flow path while maintaining a low-dead-volume internal flow path and stands firm against aqueous acids, bases, and alcohols during regular handling. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • DNA and RNA pass through with negligible adsorptive loss
    • Non-hydrogen-bonding surface avoids the polar adsorption nylon's amide backbone causes
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
    • Aromatic sulfone backbone underlies stability across the full pH range
    • High flow rate pairs with a low extractable background

    Housing Characteristics

    • Medical-grade polypropylene with broad chemical compatibility
    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Housing retains dimensional stability and seal integrity through elevated-temperature operation up to 121°C
    • Plasticizer-free polyolefin construction keeps the fluid path clean

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. General-purpose aqueous filtration supports the sample types you handle every day across your water-analysis and general analytical workflows. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    2.3 bar (33 psi)
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    13mm
    Filtration Area
    1.3cm²
    Holdup Volume
    <25µl
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    500
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 10ml
    Wettability
    Hydrophilic
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • Serum Filtration - Clarifies serum and plasma samples quickly while retaining critical proteins needed for accurate downstream analytical testing.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.