Chat with us, powered by LiveChat

Secure Checkout
Pura Disc 13mm PTFE Syringe Filters, 0.2um, 500 Pk

Thumbnail Filmstrip of Pura Disc 13mm PTFE Syringe Filters, 0.2um, 500 Pk Images

    Purchase Pura Disc 13mm PTFE Syringe Filters, 0.2um, 500 Pk

    Pura Disc 13mm PTFE Syringe Filters, 0.2um, 500 Pk
    Whatman SKU: 6783-1302

    $1,306.95
    Ships in 10 business days
     

    Whatman Puradisc PTFE Syringe Filters, 0.2 µm, 13 mm, 500/Pk - 6783-1302

    Whatman verifies performance ratings at the lot level using process controls that stay uniform across its entire filtration lineup. Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. The PTFE membrane withstands aggressive organics that degrade other media while achieving sterile-grade retention in gas and vent service and repels water while passing gases and solvents freely. The polypropylene housing maintains its geometry through sample runs up to 121°C while sustaining efficient flow on viscous samples and holds its seal true run after run. Downstream equipment and work areas stay protected from airborne bacterial contamination once the vent path runs through the membrane.

    Membrane Characteristics

    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Chemical resistance spans the full pH 1 to 14 range
    • Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
    • High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
    • Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration

    Housing Characteristics

    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Medical-grade polypropylene with broad chemical compatibility
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    1.0 bar (15 psi) [IPA]
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    13mm
    Filtration Area
    1.3cm²
    Holdup Volume
    <25µl
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    500
    Pore Size (µm)
    0.2
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 10ml
    Wettability
    Hydrophobic
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Non-Aqueous CE - Prepares non-aqueous electrophoresis samples with low background noise for clean, high-resolution separation and analysis.
    • Water Monitoring - After alcohol pre-wet, PTFE's chemical inertness holds up through repeated environmental sample runs without degrading.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.