Whatman Puradisc PTFE Syringe Filters, 0.1 µm, 13 mm, 100/Pk - 6784-1301
Whatman standardizes its manufacturing platform to the point that consistency and thorough lot-level records come as a default, exactly what analytical laboratory work demands. A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. PTFE suits solvent and reagent filtration where other membranes fail and provides bacterial retention in gas and vent streams. The PP housing sustains efficient flow on viscous samples while preserving sample chemistry across the flow path and stands firm against aqueous acids, bases, and alcohols during regular handling. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Validated against an aerosol Brevundimonas diminuta bacterial challenge
- Biological inertness resists enzymatic attack from proteases and lipases
- Inert composition offers no nutrient source for microbial growth
- Water contact angle near 120 degrees marks strong hydrophobicity
Housing Characteristics
- Resists stress cracking from aqueous salt and buffer solutions
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Minimal extractable release from the housing supports sensitive analytical work downstream
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 13mm
- Filtration Area
- 1.3cm²
- Holdup Volume
- <25µl
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 100
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 10ml
- Wettability
- Hydrophobic
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
- Venting Applications - Protects vacuum pumps and vents bioreactors using a hydrophobic PTFE membrane that forms a reliable air barrier.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.