    Whatman Puradisc PTFE Syringe Filters, 0.1 µm, 25 mm, 50/Pk - 6784-2501

    Whatman has built such a strong track record in published methods that laboratories default to citing its name in standardized protocols. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. Chemically inert PTFE achieves sterile-grade retention in gas and vent service and suits gas, vent, and solvent-stream filtration. The PP housing sustains efficient flow on viscous samples while leaving no seam for sample to bypass the membrane and stays inert across common laboratory solvents. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.

    Membrane Characteristics

    • High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
    • Non-wetting pore surface blocks liquid water while passing water vapor freely
    • Minimal moisture absorption pairs with a low tare mass
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • Insolubility in all known organic solvents avoids swelling and pore distortion

    Housing Characteristics

    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Housing retains dimensional stability and seal integrity through elevated-temperature operation up to 121°C

    Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request Whatman's performance credentials before you commit to a filtration standard requiring documented quality.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    25mm
    Filtration Area
    4.2cm²
    Holdup Volume
    <100µl
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    50
    Pore Size (µm)
    0.1
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophobic
    • Venting Applications - Protects vacuum pumps and vents bioreactors using a hydrophobic PTFE membrane that forms a reliable air barrier.
    • Water Monitoring - After alcohol pre-wet, PTFE's chemical inertness holds up through repeated environmental sample runs without degrading.
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.