Whatman Puradisc PTFE Syringe Filters, 0.45 µm, 25 mm, 200/Pk - 6785-2504
Whatman draws on Cytiva's broader manufacturing oversight while continuing a legacy of filtration work that touches laboratory research, environmental monitoring, and industrial processing alike. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE delivers absolute particle cutoff at the rated pore size while suiting gas, vent, and solvent-stream filtration and handles concentrated acids and bases. Polypropylene construction maintains a low-dead-volume internal flow path while sustaining structural integrity through elevated-temperature filtration operations and delivers a chemically clean filtrate to the downstream step. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.
Membrane Characteristics
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
- Water contact angle near 120 degrees marks strong hydrophobicity
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Ionic and metallic extractable levels stay very low
- Biological inertness resists enzymatic attack from proteases and lipases
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Thermal-bonded construction keeps adhesives out of the fluid path
- The seal formed against the membrane blocks bypass at rated operating pressure
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request details on payment terms or standing-order arrangements for your routine filtration purchases.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 0.6 bar (9 psi) [IPA]
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.2cm²
- Flow Rate
- ~30 (MeOH)
- Holdup Volume
- <100µl
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 200
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophobic
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Venting Applications - Protects vacuum pumps and vents bioreactors using a hydrophobic PTFE membrane that forms a reliable air barrier.
- UV Spectroscopy - Clarifies solvent-based samples before UV/Vis analysis, removing scattering particulates for precise, reliable absorbance readings.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.