Whatman Puradisc PTFE Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - 6798-2502
Whatman maintains in-house specialists who set and verify material specifications separately for its cellulose, glass-fiber, and polymer membrane chemistries, tailoring quality control to how each one behaves in use. A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. The PTFE matrix handles concentrated acids and bases across demanding methods while providing bacterial retention in gas and vent streams and withstands aggressive organics that degrade other media. The polypropylene housing holds its seal true run after run and maintains a low-dead-volume internal flow path. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- Insolubility in all known organic solvents avoids swelling and pore distortion
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Node-fibril microstructure resists compaction under sustained operating pressure
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Minimal moisture absorption pairs with a low tare mass
Housing Characteristics
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- Minimal extractable release from the housing supports sensitive analytical work downstream
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request Whatman's quality documentation to support your filtration step meeting a recognized laboratory-science standard.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 1.0 bar (15 psi) [IPA]
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.2cm²
- Flow Rate
- ~20 (MeOH)
- Holdup Volume
- <100µl
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophobic
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Venting Applications - Protects vacuum pumps and vents bioreactors using a hydrophobic PTFE membrane that forms a reliable air barrier.