Whatman ReZist PTFE Syringe Filters, 0.45 µm, 30 mm, 500/Pk - 10463515
Whatman standardizes its manufacturing platform to the point that consistency and thorough lot-level records come as a default, exactly what analytical laboratory work demands. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service while maintaining absolute retention consistency at every rated size and suits gas, vent, and solvent-stream filtration. The polypropylene housing routes flow to minimize backpressure in service while preserving sample chemistry across the flow path and presses snugly against the membrane during the pass. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Membrane Characteristics
- Minimal moisture absorption pairs with a low tare mass
- Non-wetting pore surface blocks liquid water while passing water vapor freely
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- The seal formed against the membrane blocks bypass at rated operating pressure
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work from reaction mixtures and crude extracts through further processing. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 0.6 bar (9 psi) [IPA]
- Connection Type
- Luer-Lok/ Luer Slip
- Diameter
- 30mm
- Filtration Area
- 7.07cm²
- Material
- Polytetrafluoroethylene (PTFE)
- Pack Count
- 500
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 150ml
- Wettability
- Hydrophobic
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Venting Vessels - Vents small laboratory flasks and bottles, acting as a protective barrier that keeps out contaminants while allowing airflow.
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Moisture Barrier - Protects sensitive sensors from aqueous aerosols using a hydrophobic membrane that blocks liquid water while passing gas.