Whatman ReZist PTFE Syringe Filters, 1 µm, 30 mm, 100/Pk - 10463523
Whatman draws on Cytiva's broader manufacturing oversight while continuing a legacy of filtration work that touches laboratory research, environmental monitoring, and industrial processing alike. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. PTFE delivers absolute particle cutoff at the rated pore size while suiting gas, vent, and solvent-stream filtration and withstands aggressive organics that degrade other media. Low-extractable polypropylene keeps sample purity intact through the filtration pass and stays inert across common laboratory solvents. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- Low extractables keep the chromatographic background clean
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Water contact angle near 120 degrees marks strong hydrophobicity
- Absolute pore rating delivers reproducible retention across every protocol
- Minimal moisture absorption pairs with a low tare mass
Housing Characteristics
- PP housing rated to 121°C holds its geometry through high-temperature sample preparation and processing
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Plasticizer-free polyolefin construction keeps the fluid path clean
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work so your downstream method starts with a clean sample. Request volume pricing and stock availability on your filtration product selection from the Tisch Scientific team.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Connection Type
- Luer-Lok/ Luer Slip
- Diameter
- 30mm
- Filtration Area
- 7.07cm²
- Material
- Polytetrafluoroethylene (PTFE)
- Pack Count
- 100
- Pore Size (µm)
- 1
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Volume Throughput (ml)
- Up to 150ml
- Wettability
- Hydrophobic
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Industrial Fluids - Filters oils and lubricants for analysis, handling viscous industrial fluids to monitor particulate levels for maintenance.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.