Chat with us, powered by LiveChat

Secure Checkout
GF Syringe Filters w/ 3 Pre-Filters, 1.2 um, 25mm, Nonsterile, 100/Pk

Thumbnail Filmstrip of GF Syringe Filters w/ 3 Pre-Filters, 1.2 um, 25mm, Nonsterile, 100/Pk Images

    Purchase GF Syringe Filters w/ 3 Pre-Filters, 1.2 um, 25mm, Nonsterile, 100/Pk

    GF Syringe Filters w/ 3 Pre-Filters, 1.2 um, 25mm, Nonsterile, 100/Pk
    Tisch SKU: SF18299

    $222.99
    Ships in 4 weeks
     

    Tisch Scientific Glass Fiber (GF) Syringe Filters, 1.2 µm, 25 mm, 100/Pk - SF18299

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Inorganic glass fiber offers broad chemical compatibility for demanding samples and accepts water-based samples on contact. The PP housing sustains efficient flow on viscous samples while holding its seal true run after run and stays inert across common laboratory solvents. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Prefiltration

    • Layered glass fiber and polypropylene depth media
    • High dirt-holding capacity for the heaviest particulate loads
    • Depth media that capture particulate through their full thickness
    • Media graded from coarse to fine across the stack

    Membrane Characteristics

    • Inorganic matrix withstands repeated aqueous exposures without swelling or structural change
    • Low-ash borosilicate fiber keeps inorganic contamination minimal in analytical filtrates
    • Borosilicate glass contributes no extractable organic background to the filtrate
    • Biologically inert borosilicate fiber with broad chemical compatibility
    • Inorganic fiber composition resists biodegradation during extended holding or room-temperature storage

    Housing Characteristics

    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Rigid polypropylene body maintains its geometry through routine filtration pressure

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. General-purpose aqueous filtration supports the sample types you handle every day from reagent and buffer preparation through routine sample clarification. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Connection Type
    Luer-Lok/Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    250ml
    Holdup Volume
    400µl
    Material
    Glass Fiber (GF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    250-290µm
    Pack Count
    100
    Pore Size (µm)
    1.2
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    GF+PP+GF
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.70
    Wettability
    Hydrophilic
    • Soil Pesticide Analysis - Glass fiber removes soil matrix particles from agricultural extracts ahead of GC-MS and LC-MS pesticide residue testing.
    • High Load Prep - Delivers exceptional dirt-loading capacity for filtering difficult, particulate-laden samples without early clogging today.
    • Botanical Extract Prep - Glass fiber removes plant cell wall debris from botanical extracts ahead of active constituent and contaminant analysis.
    • Suspension Culture - Depth filtration structure keeps shear stress low during harvest clarification, limiting cell lysis and contaminant release.
    • Feed and Forage Analysis - Glass fiber removes undissolved feed matrix particles ahead of nutrient extraction and proximate composition analysis.
    • Air Sampling Extract Prep - Glass fiber removes insoluble particulates from air filter extracts ahead of metals and organic compound analysis.