Chat with us, powered by LiveChat

Secure Checkout
Hydrophilic PTFE Syringe Filters w/ 3 Pre-Filters, 0.45 um, 25mm, 100 /Pk

Thumbnail Filmstrip of Hydrophilic PTFE Syringe Filters w/ 3 Pre-Filters, 0.45 um, 25mm, 100 /Pk Images

    Purchase Hydrophilic PTFE Syringe Filters w/ 3 Pre-Filters, 0.45 um, 25mm, 100 /Pk

    Hydrophilic PTFE Syringe Filters w/ 3 Pre-Filters, 0.45 um, 25mm, 100 /Pk
    Tisch SKU: SF18303

    $199.99
    Ships in 4 weeks
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 25 mm, 100/Pk - SF18303

    Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. Treated PTFE wets directly with aqueous samples while keeping solvent resistance while handling concentrated acids and strong bases and clarifies solvent streams at the rated pore size. The polypropylene housing presses snugly against the membrane during the pass and sustains efficient flow on viscous samples. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Prefiltration

    • Nominal depth rating sized for coarse particulate capture
    • Layered glass fiber and polypropylene depth media
    • Depth media that capture particulate through their full thickness
    • High dirt-holding capacity for the heaviest particulate loads

    Membrane Characteristics

    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
    • Ionic and metallic extractable levels stay very low
    • Chemical resistance spans the full pH 1 to 14 range

    Housing Characteristics

    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Stable across the full aqueous pH range in routine sample work
    • Minimal extractable release from the housing supports sensitive analytical work downstream

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    21.75psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    35ml
    Holdup Volume
    100μL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    GF+GF+PP
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.