Chat with us, powered by LiveChat

Secure Checkout
Hydrophobic PTFE Syringe Filter, 0.22µm, 13mm, Luer-Lok, Nonsterile, 100/Pk

Thumbnail Filmstrip of Hydrophobic PTFE Syringe Filter, 0.22µm, 13mm, Luer-Lok, Nonsterile, 100/Pk Images

    Purchase Hydrophobic PTFE Syringe Filter, 0.22µm, 13mm, Luer-Lok, Nonsterile, 100/Pk

    Hydrophobic PTFE Syringe Filter, 0.22µm, 13mm, Luer-Lok, Nonsterile, 100/Pk
    LabExact SKU: LE-IWT-ES10017

    $113.95 $173.55
    Save $59.60
     

    LabExact PTFE Syringe Filters, 0.22 µm, 13 mm, 100/Pk - LE-IWT-ES10017

    Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. The hydrophobic PTFE membrane provides bacterial retention in gas and vent streams while suiting solvent filtration where other membranes fail and resists attack from the harshest process chemistries. Polypropylene construction maintains a low-dead-volume internal flow path and leaves no seam for sample to bypass the membrane. Downstream equipment and work areas stay protected from airborne bacterial contamination once the vent path runs through the membrane.

    Membrane Characteristics

    • Ionic and metallic extractable levels stay very low
    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Validated against an aerosol Brevundimonas diminuta bacterial challenge
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack

    Housing Characteristics

    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream

    Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Diameter
    13mm
    Environmental Express Equivalent
    SF122T
    Material
    Polytetrafluoroethylene (PTFE)
    MFS/Advantec Equivalent
    13JP020AN
    Millipore Equivalent
    SLFG013NL
    Pack Count
    100
    Pall Equivalent
    4423
    Pore Size (µm)
    0.22
    Sartorius Equivalent
    17573----------K
    Sterility
    Nonsterile
    Weight
    0.168
    Wettability
    Hydrophobic
    Whatman Equivalent
    6784-1302
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
    • Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.

    Related Products