Chat with us, powered by LiveChat

Secure Checkout
WCN WH 47mm 0.65 um 100/Pk

Thumbnail Filmstrip of WCN WH 47mm 0.65 um 100/Pk Images

    Purchase WCN WH 47mm 0.65 um 100/Pk

    WCN WH 47mm 0.65 um 100/Pk SKU: 7186-004

    $271.99 $288.00
    Save $16.01
    Ships in 10 business days
     

    Cellulose Nitrate (CN) Membrane Filters - 7186-004

    The Whatman 7186-004 protects sensitive instrumentation and sample integrity by providing reliable particulate removal with minimal analyte adsorption or background interference. Central to its design, precision membrane geometry balances retention sharpness with sustainable flow rates, minimizing the pressure buildup that leads to premature filter replacement. In effect, consistent surface properties across the full membrane area support uniform particle capture and reliable results in gravimetric, microscopic, and culture-based analytical workflows.

    Material Specifications

    • Autoclavable at 121°C without loss of integrity, cellulose nitrate membranes maintain their rated pore structure and dimensional stability through repeated sterilization cycles.
    • Cellulose nitrate membranes feature a narrow pore size distribution and low extractable levels, providing the controlled retention characteristics required for gravimetric and particulate analysis.
    • Surface retention characteristics allow captured particles and microorganisms to remain on the membrane face, supporting direct microscopic examination and physical recovery of collected material.
    • High protein binding capacity makes cellulose nitrate the preferred membrane for Western blotting, dot blotting, and nucleic acid immobilization techniques that rely on efficient surface adsorption.
    • Non-sterile configuration is suited for analytical sample preparation, mobile phase filtration, and other workflows where pre-sterilization is not required.

    Transitioning from qualitative screening to quantitative gravimetric analysis requires a membrane with documented tare weight consistency, and the manufacturing tolerances above ensure that your blank values remain within acceptable limits. Here, surface retention on cellulose nitrate keeps captured particles and microorganisms on the membrane face where they remain accessible for direct microscopic examination, colony counting, and physical recovery without sectioning or dissolution. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    35.0psi
    Color
    white
    Diameter
    47mm
    Extractables
    low
    Filtration Area
    17.35cm²
    Flow Rate
    110ml (Water)
    Grid (Yes/No)
    No
    Material
    Cellulose Nitrate (CN)
    Maximum Operating Pressure
    Holder-dependent
    Maximum Operating Temperature (°C)
    80°C
    Membrane Thickness (µm)
    105–140um
    Pack Count
    100
    pH Range
    4-9
    Pore Size (µm)
    0.65
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 30 mins
    Support Material
    None
    Wettability
    Hydrophilic
    • Routine Sample Prep - Uniform microporous matrix provides consistent flow rates and reliable particle retention for general aqueous solutions.
    • Water Quality Testing - Narrow pore distribution retains indicator organisms consistently for regulatory compliance in environmental laboratories.
    • Colony Enumeration - Gridded surface variants facilitate accurate plate counting of captured microorganisms under standard magnification.
    • Biochemical Assays - High protein-binding capacity effectively immobilizes macromolecules, supporting lateral flow and diagnostic testing.
    • Aerosol Analysis - Low tare weight and acid digestibility enable chemical characterization of airborne particulates from air sampling.
    • Bioburden Monitoring - Surface retention keeps captured organisms accessible for direct incubation and enumeration without transfer steps.