Cellulose Nitrate Membrane Circle, Plain, 12 um, 50mm, 100/Pk

Thumbnail Filmstrip of Cellulose Nitrate Membrane Circle, Plain, 12 um, 50mm, 100/Pk Images

    Purchase Cellulose Nitrate Membrane Circle, Plain, 12 um, 50mm, 100/Pk

    Cellulose Nitrate Membrane Circle, Plain, 12 um, 50mm, 100/Pk SKU: 10400014

    $280.99 $298.00
    Save $17.01
    Ships in 3 weeks
     

    Cellulose Nitrate (CN) Membrane Filters - 10400014

    The Whatman 10400014 protects sensitive instrumentation and sample integrity by providing reliable particulate removal with minimal analyte adsorption or background interference. Precision membrane geometry balances retention sharpness with sustainable flow rates, minimizing the pressure buildup that leads to premature filter replacement. Precision manufacturing ensures that each membrane disc delivers the rated retention, flow rate, and surface consistency that analytical and microbiological methods require.

    Material Specifications

    • High protein binding capacity makes cellulose nitrate the preferred membrane for Western blotting, dot blotting, and nucleic acid immobilization techniques that rely on efficient surface adsorption.
    • Naturally hydrophilic and compatible with aqueous solutions, cellulose nitrate delivers high flow rates and rapid wet-out without requiring pre-conditioning or surfactant treatment.
    • Packaged without sterilization for applications where downstream sterility is achieved by other means or is not a process requirement.
    • Surface retention characteristics allow captured particles and microorganisms to remain on the membrane face, supporting direct microscopic examination and physical recovery of collected material.
    • Autoclavable at 121°C without loss of integrity, cellulose nitrate membranes maintain their rated pore structure and dimensional stability through repeated sterilization cycles.

    Reproducible particle counting and size distribution analysis start with a membrane surface that captures particles uniformly — the pore consistency documented above ensures your counts reflect the sample, not random variation in the filter. Cellulose nitrate's dimensional stability through autoclaving at 121°C means your membranes maintain their rated pore structure and physical dimensions from pre-sterilization through final analysis, supporting method reproducibility. Make the decision for consistency and reliability, ensuring that your laboratory maintains its reputation for high-quality, error-free output.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    N/A
    Color
    white
    Diameter
    50mm
    Extractables
    low
    Filtration Area
    19.63cm²
    Flow Rate
    450ml (Water)
    Grid (Yes/No)
    No
    Material
    Cellulose Nitrate (CN)
    Maximum Operating Pressure
    Holder-dependent
    Maximum Operating Temperature (°C)
    80°C
    Membrane Thickness (µm)
    105–140um
    Pack Count
    100
    pH Range
    4-8
    Pore Size (µm)
    12
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 30 mins
    Support Material
    None
    Wettability
    Hydrophilic
    • Water Quality Testing - Narrow pore distribution retains indicator organisms consistently for regulatory compliance in environmental laboratories.
    • Routine Sample Prep - Uniform microporous matrix provides consistent flow rates and reliable particle retention for general aqueous solutions.
    • Colony Enumeration - Gridded surface variants facilitate accurate plate counting of captured microorganisms under standard magnification.
    • Bioburden Monitoring - Surface retention keeps captured organisms accessible for direct incubation and enumeration without transfer steps.
    • Aerosol Analysis - Low tare weight and acid digestibility enable chemical characterization of airborne particulates from air sampling.
    • Environmental Compliance - Documented retention characteristics at standard pore ratings support reproducibility in regulated testing programs.