    Nylon Membrane Filters - 7402-002

    The Whatman 7402-002 protects sensitive instrumentation and sample integrity by providing reliable particulate removal with minimal analyte adsorption or background interference. Underpinning this performance, quality-controlled manufacturing ensures the filtration medium delivers the retention efficiency and throughput that demanding laboratory protocols require. Each membrane disc reflects a manufacturing standard where retention characteristics, physical integrity, and dimensional accuracy are verified before release.

    Material Specifications

    • Naturally hydrophilic and constructed with high tensile strength, Nylon provides reliable performance without pre-wetting in aqueous applications.
    • Packaged without sterilization for applications where downstream sterility is achieved by other means or is not a process requirement.
    • High mechanical strength allows Nylon membranes to withstand elevated differential pressures without structural deformation.
    • Broad compatibility with alcohols, aliphatic hydrocarbons, and aromatic solvents extends Nylon filtration into mixed-solvent sample preparation.
    • Ideal for filtering aqueous biological solutions and mobile phases.

    Environmental monitoring programs where sample-to-sample comparability determines trend validity benefit directly from the lot-level consistency of these membranes, removing the filter as a variable in your long-term data sets. In these cases, alkaline resistance that other membranes cannot match means you can filter high-pH buffers, basic mobile phases, and caustic wash solutions without the membrane degradation that limits cellulose-based and PES alternatives. Elevate the quality of your analytical data today by standardizing on a filtration product built to meet the exact specifications of your applications.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    40-49psi
    Color
    white
    Diameter
    25mm
    Extractables
    low
    Filtration Area
    4.91cm²
    Flow Rate
    > 50ml (Water)
    Grid (Yes/No)
    No
    Material
    Nylon
    Maximum Operating Pressure
    Holder-dependent
    Maximum Operating Temperature (°C)
    135°C
    Membrane Thickness (µm)
    150-187um
    Pack Count
    100
    pH Range
    3-14
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 30 mins
    Support Material
    None
    Wettability
    Hydrophilic
    • Solid Phase Extraction - Acts as a frit or barrier in custom extraction columns, retaining sorbent beds while allowing solvent to pass through.
    • Atmospheric Testing - Used in dry deposition sampling to capture specific atmospheric nitrates and sulfates for environmental quality studies.
    • Northern Blotting - Excellent for RNA transfer applications where high tensile strength is required for multiple rounds of probe stripping.
    • Gene Mapping Support - Provides a stable, charge-modified surface for DNA immobilization, facilitating precise gene mapping and analysis steps.
    • Southern Blot Transfer - Binds nucleic acids strongly during capillary transfer, providing a durable matrix for repeated hybridization cycles.
    • Alkaline Filtration - Withstands high-pH solutions during industrial fluid processing, offering durability where other polymers might degrade.