    Nylon Capsule Filters - SF14913

    The naturally hydrophilic structure of nylon capsule filters eliminates pre-wetting requirements, enabling immediate use with aqueous solutions while maintaining compatibility with most organic solvents. On the performance side, the broad solvent compatibility of nylon membrane extends across aqueous, alcoholic, and mixed organic systems, providing a single capsule platform for laboratories filtering diverse reagent types at volume. The result is a streamlined filtration step that integrates directly into fluid transfer systems, reducing hold times and minimizing the manual handling that compromises sterility assurance.

    Key Nylon Membrane Characteristics

    • The non-sterile format provides the same membrane retention and flow performance as sterile variants, with the flexibility for user-controlled sterilization when process requirements dictate.
    • Rated for continuous operation at temperatures up to 80 degrees Celsius, the capsule maintains structural integrity and retention performance across the normal process temperature range.
    • The mechanical strength of nylon membrane construction supports the operating pressures encountered in capsule filtration systems without the deformation risks associated with thinner membrane materials.
    • Internal holdup volume of 60 milliliters minimizes sample loss during capsule filtration, a critical consideration when processing expensive biologics or limited-volume preparations.
    • The broad solvent compatibility of nylon membranes extends across aqueous, alcoholic, and many organic systems, providing a versatile capsule platform for laboratories processing diverse reagent types.

    Key Capsule Construction Features

    • The sealed polypropylene housing is individually integrity-tested during manufacturing, verifying membrane installation and housing seal quality before the device leaves the production facility.
    • Polypropylene capsule housing supports autoclave sterilization at 121 degrees Celsius and withstands gamma irradiation exposure, accommodating both user-sterilized and factory-sterilized device configurations.
    • Thermally fused polypropylene construction eliminates adhesives, binders, and O-rings from the fluid path, reducing extractable contamination and simplifying material qualification.
    • Polypropylene housing materials provide documented biocompatibility and low extractable profiles, supporting integration into pharmaceutical and food-processing filtration applications.

    As single-use filtration continues to replace reusable housings across pharmaceutical and laboratory environments, your capsule filter selection determines both the quality of the filtrate and the efficiency of the workflow. In these cases, if your laboratory processes diverse aqueous and organic solutions, the natural hydrophilicity and broad solvent compatibility of nylon membrane construction simplifies your workflow across application types. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.

    Sterilization Guidance

    Polypropylene construction throughout the device permits autoclave sterilization at standard conditions, enabling end-user preparation for sterile filtration applications as needed.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    23.2psi
    Compliance Standards
    ISO 9001
    Connection Type
    1/4 in. MNPT
    Construction
    Polypropylene
    Diameter
    72mm
    Dimensions
    72mm x 115mm
    Filling Bell (Yes/ No)
    No
    Filtration Area
    1000cm²
    Flow Rate
    1.25 L/min at 0.1 bar
    Holdup Volume
    60mL
    Inlet Connection
    1/4 in. MNPT
    Length
    115mm
    Material
    Nylon
    Max Batch Volume
    <50L
    Maximum Operating Pressure
    75.4psi
    Maximum Operating Temperature (°C)
    80°C
    Outlet Connection
    1/4 in. MNPT
    Pack Count
    1
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 30 mins
    Vent (Yes/ No)
    Yes
    Weight
    0.39
    Wettability
    Hydrophilic
    • Chemical Solutions - Filtration of alcohols, esters, and mild organic solvents compatible with the broad chemical tolerance of nylon membranes.
    • Environmental Samples - Processing of water, soil extract, and environmental samples requiring both particulate removal and volume capacity.
    • Aqueous Processing - Hydrophilic membrane filtration of water-based solutions with immediate wetting and full surface area utilization.
    • Reagent Preparation - General-purpose filtration of laboratory reagents, buffers, and chemical solutions across aqueous and organic systems.
    • Buffer Filtration - Removal of particulates from biological and chemical buffers prior to analytical instrumentation or process use.
    • Laboratory General - Versatile capsule filtration platform for multi-application laboratories processing diverse solution types at volume.