Tisch Scientific Nylon Syringe Filters, 0.45 µm, 25 mm, 100/Pk - GD17034
Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. The nylon membrane resists alkaline conditions across a broad buffer range while wetting on contact with aqueous buffers and fits routine analytical sample preparation. Polypropylene construction resists chemical degradation from routine sample matrices while routing flow to minimize backpressure in service and preserves sample chemistry across the flow path. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.
Prefiltration
- Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
- Depth-loading glass fiber matrix captures particulate throughout its full thickness
- Added glass fiber stage extends usable throughput by delaying membrane clogging
- High dirt-holding capacity suits very turbid, high-solids sample loads
Membrane Characteristics
- Saturation moisture uptake reaches up to 8% by resin weight
- Resonance-stabilized amide bonds anchor nylon's resistance to alkaline hydrolysis
- Tortuous, reticulated pore structure yields more usable filtration area than capillary-pore membranes
- Solvent compatibility extends to both acetonitrile and methanol
- Non-sterile format suits HPLC and GC sample clarification
Housing Characteristics
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Resists stress cracking from aqueous salt and buffer solutions
- Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion
- The seal formed against the membrane blocks bypass at rated operating pressure
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. General-purpose aqueous filtration supports the sample types you handle every day from reagent and buffer preparation through routine sample clarification. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 23.0psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 24.0ml
- Holdup Volume
- 100ul
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- GF
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 100ml
- Weight
- 0.70
- Wettability
- Hydrophilic
- GC Sample Prep - Clarifies aqueous and organic extracts ahead of gas chromatography injection, protecting inlets from particulate fouling.
- Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.
- Chemical Analysis - Withstands aggressive bases and alcohols, ideal for tough chemical compatibility filtration challenges in routine analysis.
- Environmental Extract Prep - Clarifies water and soil extracts ahead of trace metals or pesticide-residue analysis for accurate results.
- Ink and Dye Filtration - Filters aqueous and solvent-based inks and dyes, removing pigment agglomerates ahead of color strength analysis.
- Buffer Filtration - Delivers high mechanical strength for efficient clarification of alkaline buffers and aqueous reagents in the lab.