Tisch Scientific Nylon Syringe Filters, 0.22 µm, 25 mm, 100/Pk - SF02225NP
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Naturally hydrophilic nylon accepts water-based samples without surfactant preconditioning while resisting alkaline buffer systems and reaches bacteria-retentive performance across sub-micron pore range. The PP housing stays inert across common laboratory solvents and buffers in routine use and sheds virtually no extractable material into the sample. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Membrane Characteristics
- Saturation moisture uptake reaches up to 8% by resin weight
- Moisture-plasticized amide linkages raise membrane impact toughness over dry resin
- Tortuous, reticulated pore structure yields more usable filtration area than capillary-pore membranes
- Autoclaving at 121°C for 30 minutes leaves pore structure intact
- Solvent compatibility extends to both acetonitrile and methanol
Housing Characteristics
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Upstream buffer clarification keeps your run from stalling on particulates that slipped through while keeping the filtrate analytically clean. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 37.5psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 2.98cm²
- Flow Rate
- 6.0ml
- Holdup Volume
- 50ul
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 50ml
- Weight
- 0.52
- Wettability
- Hydrophilic
- Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.
- Column Protection - Extends the life of analytical columns by reliably removing micro-particulates from aqueous mobile phases in HPLC.
- Forensic Toxicology Screening - Clarifies urine and blood extracts ahead of LC-MS or GC-MS analysis in forensic drug-screening laboratories.
- Chemical Analysis - Withstands aggressive bases and alcohols, ideal for tough chemical compatibility filtration challenges in routine analysis.
- HPLC Sample Prep - Clarifies mixed aqueous and organic solvents to ensure stable baselines and protect chromatography columns from clogging.
- HPLC Pump Protection - Filters reservoir solvent to prevent particulates from abrading pump check valves and seals over time.