Tisch Scientific Nylon Syringe Filters, 0.22 µm, 25 mm, 100/Pk - SF13829
Tisch Scientific works with established filtration manufacturers to ensure reliable quality and performance. Under hand pressure from the syringe, the membrane captures particulates as the sample passes through. The nylon matrix resists particle shedding through extended filtration cycles while resisting alkaline buffer systems and supports high-volume routine filtration. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while contributing minimal extractables to the filtrate and holds a reliable seal against the membrane edge. When chromatographic methods demand particle-free injections, point-of-use syringe filtration clarifies the sample before it reaches the column.
Technical Specifications
- Naturally hydrophilic surface wets without pre-wetting in aqueous applications
- Stable across the pH 3 to 12 operating range
- Broad compatibility with alcohols, aliphatic, and aromatic solvents
- Alkaline-resistant across a broad range of aqueous buffers
- Low extractable contribution to sensitive analytical preparations
Housing Specifications
- Resists aqueous acids, bases, and alcohols in routine sample prep
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Thermal-bonded construction keeps adhesives out of the fluid path
Filtering buffers, reagents, and aqueous samples keeps your preparation moving and consistent. Consistent aqueous clarification keeps your sample preparation moving across the buffers and reagents your methods rely on. Reach out to the Tisch Scientific team for application support, volume pricing, and technical assistance with your filtration product selection.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 35.0psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 10.0ml
- Holdup Volume
- 100ul
- Incompatibility
- Acids, agressive organics, protein
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 100ml
- Weight
- 0.52
- Wettability
- Hydrophilic
- Bacterial Retention - Retains bacteria from aqueous buffers to significantly reduce bioburden in research and analytical protocols
- HPLC Mobile Phase Preparation - Filters mobile phases to remove sub-micron particulates and protect analytical columns from premature fouling
- Chemical Solvent Filtration - Clarifies organic solvents and alkaline solutions compatible with nylon membranes for analytical applications
- Pharmaceutical Bioburden Reduction - Reduces microbial load in drug formulations to ensure quality control in pharmaceutical manufacturing workflows
- Laboratory Reagent Filtration - Removes fine particulates and bacteria from buffers to ensure consistency in contamination-sensitive protocols
- Environmental Water Analysis - Retains bacteria from water samples for microbiological testing in environmental monitoring and wastewater analysis