Tisch Scientific Nylon Syringe Filters, 0.22 µm, 13 mm, 100/Pk - SF14478
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. Nylon provides sterile-grade retention at sub-micron pore size and holds dimensional stability under rated backpressure. Polypropylene construction resists chemical degradation from routine sample matrices and sheds virtually no extractable material into the sample. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Saturation moisture uptake reaches up to 8% by resin weight
- Polar amide backbone gives high native affinity for nucleic acids
- Synthetic polyamide backbone resists microbial and enzymatic degradation unlike cellulose membranes
- Solvent compatibility extends to both acetonitrile and methanol
- Ester- and alcohol-resistant across common laboratory sample preparations
Housing Characteristics
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Impact-tolerant polypropylene body withstands routine bench handling without damage
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
Particulates that reach your column with the sample foul the frits and shorten its life. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 37.5psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 2.0ml
- Holdup Volume
- 20ul
- Incompatibility
- Acids, agressive organics, protein
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophilic
- Beverage QC Clarification - Clarifies wine, beer, and juice samples ahead of analytical and microbiological testing in quality control labs.
- Amino Acid Profiling - Clarifies aqueous sample digests for HPLC and LC-MS amino acid analysis in food, nutrition, and fermentation monitoring.
- Ink and Dye Filtration - Filters aqueous and solvent-based inks and dyes, removing pigment agglomerates ahead of color strength analysis.
- Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.
- UHPLC Sample Prep - Removes sub-micron debris from aqueous samples before injection, protecting narrow-bore UHPLC columns from accelerated wear.
- HPLC Sample Prep - Clarifies mixed aqueous and organic solvents to ensure stable baselines and protect chromatography columns from clogging.