Tisch Scientific Nylon Syringe Filters, 0.45 µm, 17 mm, 100/Pk - SF15591
Tisch Scientific offers competitive pricing across its filtration catalog, helping cost-conscious laboratories keep supply budgets in check. A syringe filter holds its membrane in a leak-tight housing for clarification at the bench. Nylon stays stable across the pH 3 to 12 buffer range and delivers sharp particle cutoff at the rated pore size. The polypropylene housing resists aqueous acids, bases, and alcohols and holds extractables low for sensitive analyses. Where small-volume samples must reach the instrument clean, syringe filtration clears particulates in a single pass.
Technical Specifications
- Broad compatibility with alcohols, aliphatic, and aromatic solvents
- High tensile strength for stability under elevated differential pressures
- Low extractable contribution to sensitive analytical preparations
- Naturally hydrophilic surface wets without pre-wetting in aqueous applications
- Stable across the pH 3 to 12 operating range
Housing Specifications
- Thermal-bonded construction keeps adhesives out of the fluid path
- Reliable housing-to-membrane seal prevents bypass at rated pressure
- Optimized internal geometry minimizes backpressure in service
- Medical-grade polypropylene with broad chemical compatibility
Sample clarification before injection is the cheapest insurance your chromatography system has. Upstream sample clarification keeps your separations clean and reproducible so your filtrate reaches the column clean. Review our Chemical Compatibility Chart, or ask technical service to confirm chemical compatibility for your specific application.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 23.0psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 17mm
- Filtration Area
- 1.65cm²
- Flow Rate
- 10.0ml
- Holdup Volume
- 20ul
- Incompatibility
- Acids, agressive organics, protein
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- GF
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 20ml
- Weight
- 0.33
- Wettability
- Hydrophilic
- Pharmaceutical Sample Clarification - Clarifies drug formulations and non-acidic solutions to ensure accurate results in analytical testing
- HPLC Sample Preparation - Protects analytical columns by effectively removing particulates that cause high backpressure and baseline drift
- Laboratory Solvent Clarification - Filters compatible organic and aqueous solvents to ensure contamination-free results in analytical procedures
- Organic Solvent Filtration - Clarifies solvents like DMF and alcohols to prevent particulate interference in spectroscopy and chromatography
- Buffer Preparation - Clarifies buffer solutions and mobile phases to maintain consistent baseline performance in sensitive analytical methods
- Environmental Sample Processing - Pre-filters water and soil extracts to remove sediment before chemical analysis and trace contaminant detection