Tisch Scientific Nylon Syringe Filters, 3 µm, 13 mm, 100/Pk - SF18105
Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. A syringe filter's small hold-up volume limits sample loss, a meaningful difference when working with a limited or precious sample. Nylon wets on contact with aqueous samples while stopping particulates too coarse to pass its pore opening and supports high-volume routine filtration. The polypropylene housing preserves sample chemistry across the flow path while routing flow to minimize backpressure in service and stands firm against aqueous acids, bases, and alcohols during regular handling. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- DMSO compatibility extends across sample-preparation chemistries
- Synthetic polyamide backbone resists microbial and enzymatic degradation unlike cellulose membranes
- Non-sterile format suits HPLC and GC sample clarification
- Polar amide backbone gives high native affinity for nucleic acids
- Absolute pore size rating holds consistent across every protocol
Housing Characteristics
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Rigid polypropylene body maintains its geometry through routine filtration pressure
Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Request volume pricing and stock availability on your filtration product selection from the Tisch Scientific team.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 5.5psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 60.0ml
- Holdup Volume
- 20ul
- Incompatibility
- Acids, agressive organics, protein
- Material
- Nylon
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 90-120µm
- Pack Count
- 100
- Pore Size (µm)
- 3.0
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121° C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophilic
- Buffer Filtration - Delivers high mechanical strength for efficient clarification of alkaline buffers and aqueous reagents in the lab.
- GC Sample Prep - Clarifies aqueous and organic extracts ahead of gas chromatography injection, protecting inlets from particulate fouling.
- Column Protection - Extends the life of analytical columns by reliably removing micro-particulates from aqueous mobile phases in HPLC.
- Drinking Water Analysis - Clarifies tap and source water samples ahead of metals, nitrate, and trace-contaminant compliance testing.
- Veterinary Drug Residue Testing - Clarifies meat, milk, and egg extracts ahead of LC-MS/MS screening for drug residues in food-safety laboratories.
- Chemical Analysis - Withstands aggressive bases and alcohols, ideal for tough chemical compatibility filtration challenges in routine analysis.