Tisch Scientific Nylon Syringe Filters, 5 µm, 25 mm, 100/Pk - SPEC18120
Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. The nylon matrix resists particle shedding through extended filtration cycles while accepting water-based reagents without surfactant conditioning and fits routine analytical sample preparation. The polypropylene housing holds its seal true run after run and preserves sample chemistry across the flow path. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Membrane Characteristics
- Amorphous-crystalline nylon blend composition doubles membrane burst strength over homopolymer nylon
- Polar amide backbone gives high native affinity for nucleic acids
- Saturation moisture uptake reaches up to 8% by resin weight
- Compatible with most HPLC mobile phases for sample clarification
- Non-sterile format suits HPLC and GC sample clarification
Housing Characteristics
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Thermal-bonded construction keeps adhesives out of the fluid path
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Double luer-lock connections on inlet and outlet deliver a secure, leak-resistant in-line path for continuous filtration
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 2.9psi
- Burst Pressure (psi)
- 116psi
- Connection Type
- Double Luer Lock
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 300ml/ min @ 10psi.
- Holdup Volume
- 100µl
- Incompatibility
- Acids, agressive organics, protein
- Material
- Nylon
- Maximum Operating Pressure
- 72.5psi
- Maximum Operating Temperature (°C)
- 80℃
- Pack Count
- 100
- Pore Size (µm)
- 5.0
- Sterility
- Nonsterile
- Sterilization
- Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
- Volume Throughput (ml)
- 100ml
- Weight
- 0.58
- Wettability
- Hydrophilic
- Veterinary Drug Residue Testing - Clarifies meat, milk, and egg extracts ahead of LC-MS/MS screening for drug residues in food-safety laboratories.
- Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.
- Forensic Toxicology Screening - Clarifies urine and blood extracts ahead of LC-MS or GC-MS analysis in forensic drug-screening laboratories.
- Drinking Water Analysis - Clarifies tap and source water samples ahead of metals, nitrate, and trace-contaminant compliance testing.
- Biofuel Particulate Testing - Removes particulate debris from biodiesel and fuel samples ahead of chromatographic QC analysis in fuel testing labs.
- Buffer Filtration - Delivers high mechanical strength for efficient clarification of alkaline buffers and aqueous reagents in the lab.